| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 2602-1032P1 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON ELECTRONIC SYSTEMS, INC | 04164 | |
| 10-072620-02S | 5 - Replaced / Discontinued | 2 - Production Item | AMPHENOL CORPORATION | 77820 | |
| 2602-1032P1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON SERVICE CO | 2B487 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5935 | 005814838 | A039B0 | 01938 | X | K | A | P | A | A | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZZ | ||||||||||||||||||||||||||||||
| DGX1 | 1 | H | TX | 1 Nov 2005 | ||||||||||||||||||||||||||
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Columbus, Columbus, OH 43218
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 5 | 2 | 6 | ZZ | 10-072620-02S | 77820 | | ||||||
| 5 | 9 | 5 | HD | 2602-1032P1 | 2B487 | | ||||||
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
* Special Requirements
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
1
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAQ | Body Length | 2.713 INCHES MINIMUM AND 2.722 INCHES MAXIMUM |
| AFQJ | Cable Entrance Diameter | 0.750 INCHES NOMINAL |
| AFRV | Connector Locking Method | INTERNALLY THREADED COUPLING RING |
| AFRW | Connector Cable Strain Relief Method | CABLE CLAMP |
| CQTZ | Contact Material | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRD | Contact Maximum Ac Voltage Rating In Volts | 900.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRC | Contact Maximum Current Rating In Amps | 245.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFQZ | Contact Removability | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRE | Contact Maximum Dc Voltage Rating In Volts | 1250.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFQX | Contact Position Arrangement Style | 20-2 SINGLE MATING END |
| CRBJ | Contact Surface Treatment Document And Classification | QQ-S-365 FED SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
| CQYH | Contact Surface Treatment | SILVER SINGLE MATING END SINGLE CONTACT GROUPING |
| ADZC | Environmental Protection | WATERTIGHT |
| AAQL | Body Style | STRAIGHT SHAPE, INTERNAL COUPLING W/STRAIN RELIEF |
| AFQW | Mating End Quantity | 1 |
| AKMG | Nominal Thread Length | 0.375 INCHES |
| CQJX | Nominal Thread Size | 1.250 INCHES |
| CXCG | Included Contact Quantity | 1 SINGLE MATING END SINGLE CONTACT GROUPING |
| CXCL | Included Contact Type | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
| CQZG | Insert Material | PLASTIC SINGLE MATING END |
| AFRP | Insert Position In Deg | 0.0 |
| AFRN | Polarization Method | KEYWAY OR MULTIPLE KEYWAY |
| CSPT | Shell Material | ALUMINUM ALLOY |
| CTBC | Shell Surface Treatment Document And Classification | MIL-A-8625 MIL SPEC SINGLE TREATMENT RESPONSE |
| CSWM | Shell Surface Treatment | ANODIZE |
| AFRT | Shell Type | SOLID |
| ADAV | Overall Diameter | 1.469 INCHES NOMINAL |
| CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| CSCF | Terminal Type | SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING |
| AAJD | Thread Class | 2B |
| AAJF | Thread Direction | RIGHT-HAND |
| THSD | Thread Series Designator | UNEF |
| AFQR | Threaded Device Type | COUPLING FACILITY |