5935-00-811-8635

CONNECTOR,RECEPTACLE,ELECTRICAL


5935-00-811-8635 (5935008118635, 008118635)
Part Numbers (5 listings): 369-0002-000 | GC806AF78S | 92-50285-023 | DMS82061B | 126-20753 |
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1962

Unit Weight: 1.0 lbs

Unit Size: 4in x 1.1in x 1.8in

Unit Pack Cube: 0.004 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-811-8635 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
369-0002-0003 - Design Control Reference2 - Production ItemROCKWELL COLLINS, INC.  13499    CAGE 13499  
369-0002-0005 - Replaced / Discontinued2 - Production ItemROCKWELL COLLINS, INC.  95105    CAGE 95105  
GC806AF78S5 - Replaced / Discontinued2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
92-50285-0235 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  15090    CAGE 15090  
DMS 82061B5 - Replaced / Discontinued9 - No Longer UsedDLA LAND AND MARITIME  16236    CAGE 16236  
126-207535 - Replaced / Discontinued9 - No Longer UsedAMPHENOL CORP  02660    CAGE 02660  
126-20753C - Advisory Reference1 - Incomplete Part NumberNAVCOM DEFENSE ELECTRONICS, INC.  57057    CAGE 57057  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-811-8635 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935008118635A039B015093X1APAG1 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

008118635

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-811-8635

A039B0

Federal Item Identification Guide (FIIG_4065)

15093

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-811-8635 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZU011 Apr 1991
ZR011 Jul 1997
FXGXFXTX1HZSX1 Aug 2006
MC49MC131HZPA1 Aug 2006
N9BNNIND1HZGHGTKEHD1 Aug 2006
YD011 Sep 2016
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5935-00-811-8635 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4321TXD369-0002-000  13499   CAGE/13499
525TXD92-50285-023  15090   CAGE/15090
3525KEDGC806AF78S  26512   CAGE/26512
525TX369-0002-000  95105   CAGE/95105
3593TXB126-20753  02660   CAGE/02660
599TXDMS 82061B  16236   CAGE/16236
C15ZZAC126-20753  57057   CAGE/57057
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-811-8635 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX028 Mar 1967
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Mar 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-811-8635 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5935-00-811-8635 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSVU1NEA0
DMSMSVU1ZEA0
DNSMSVU1EA0
DSSMSVU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5935-00-811-8635 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA1.0 lbs4in x 1.1in x 1.8in0.004 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00EA000D3DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

1.0 lbs

Unit Pack Weight (UP_WT_5153)

4in x 1.1in x 1.8in

Unit Pack Size (UP_SZ_5154)

0.004 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

EA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-DTL-17667, neutral wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-811-8635 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length3.544 INCHES MINIMUM AND 3.554 INCHES MAXIMUM
AFRVConnector Locking MethodFRICTION
CQTZContact MaterialBERYLLIUM SINGLE MATING END ALL CONTACT GROUPINGS AND COPPER ALLOY SINGLE MATING END ALL CONTACT GROUPINGS
AFRDContact Maximum Ac Voltage Rating In Volts325.0 SINGLE MATING END 2ND CONTACT GROUPING
AFRDContact Maximum Ac Voltage Rating In Volts650.0 SINGLE MATING END 1ST CONTACT GROUPING
CSGFContact Material Document And ClassificationQQ-C-530 FED SPEC ALL MATERIAL RESPONSES SINGLE MATING END ALL CONTACT GROUPINGS
AFQXContact Position Arrangement Style78 SINGLE MATING END
AFQZContact RemovabilityNONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS
CRBJContact Surface Treatment Document And ClassificationMIL-G-45204 MIL SPEC 1ST TREATMENT RESPONSE SINGLE MATING END 1ST CONTACT GROUPING AND QQ-S-365 FED SPEC 2ND TREATMENT RESPONSE SINGLE MATING END 1ST CONTACT GROUPING
CQYHContact Surface TreatmentGOLD SINGLE MATING END 1ST CONTACT GROUPING AND SILVER SINGLE MATING END 1ST CONTACT GROUPING
CQYHContact Surface TreatmentRHODIUM SINGLE MATING END 2ND CONTACT GROUPING AND SILVER SINGLE MATING END 2ND CONTACT GROUPING
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM
AAQLBody StyleRECTANGULAR SHAPE
AFQWMating End Quantity1
CQJXNominal Thread Size0.138 INCHES
CXCGIncluded Contact Quantity3 SINGLE MATING END 1ST CONTACT GROUPING
CXCGIncluded Contact Quantity75 SINGLE MATING END 2ND CONTACT GROUPING
CXCLIncluded Contact TypeCOAXIAL SOCKET SINGLE MATING END 2ND CONTACT GROUPING
CXCLIncluded Contact TypeROUND SOCKET SINGLE MATING END 1ST CONTACT GROUPING
CTKLInsert Material Document And ClassificationMIL-M-14 MIL SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END
CQZGInsert MaterialPLASTIC DIALLYL PHTHALATE SINGLE MATING END
AFRNPolarization MethodMATING END
PMLCPrecious Material And LocationCONTACT SURFACES GOLD AND CONTACT SURFACES SILVER AND CONTACT SURFACES RHODIUM
PMWTPrecious Material And Weight0.015 GOLD GRAINS, TROY AND 0.075 SILVER GRAINS, TROY AND 0.078 RHODIUM GRAINS, TROY
PRMTPrecious MaterialGOLD AND SILVER AND RHODIUM
AFRYRadio Frequency Type Contact Characteristic Impedance In Ohms50.0 SINGLE MATING END ALL CONTACT GROUPINGS
CTHHShell Material Document And ClassificationQQ-A-591 FED SPEC SINGLE MATERIAL RESPONSE
CSWMShell Surface TreatmentCHROMATE
AFRTShell TypeSOLID
CSPTShell MaterialALUMINUM ALLOY
CTBCShell Surface Treatment Document And ClassificationMIL-C-5541 MIL SPEC SINGLE TREATMENT RESPONSE
ABKWOverall Height1.781 INCHES NOMINAL
ABHPOverall Length3.900 INCHES MINIMUM AND 4.000 INCHES MAXIMUM
ABMKOverall Width1.120 INCHES MINIMUM AND 1.130 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END ALL CONTACT GROUPINGS
CSCFTerminal TypeSOLDER WELL SINGLE MATING END ALL CONTACT GROUPINGS
AAJDThread Class2A
AAJFThread DirectionRIGHT-HAND
THSDThread Series DesignatorUNC
CMLPThread Quantity Per Inch32
AFQRThreaded Device TypeMOUNTING STUD


Back to Top
Back to Top