| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| SP00CP-16-26SW(003) | 3 - Design Control Reference | 2 - Production Item | AMPHENOL CORPORATION | 77820 | |
| 1079-844-5 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BAE SYSTEMS INFORMATION AND | 72314 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5935 | 008430350 | A039B0 | 15093 | X | 1 | A | P | A | G | 6 Jan 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains gold.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N9BN | N9ND | 3 | L | Z | GH | KE | 1 Jul 2005 | |||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | F | ZZ | SP00CP-16-26SW(003) | 77820 | | ||||||
| 3 | 7 | 2 | 1 | TX | D | 1079-844-5 | 72314 | | ||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for limited use under the terms of the rights-in-data clause of the contract by which the data was obtained and will be furnished by the activity identified by the RNAAC upon request. Descriptive data based on Limited Rights information will not be released to the general public through publications or other media.
USA
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 2 | TX | 0 | 21 Jul 1967 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | 72D | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAQL | Body Style | STRAIGHT SHAPE, FLANGE MOUNT, EXTERNAL COUPLING |
| ABHP | Overall Length | 1.594 INCHES MAXIMUM |
| ABKW | Overall Height | 1.422 INCHES MINIMUM AND |
| ABKW | Overall Height | 1.454 INCHES MAXIMUM |
| ABMK | Overall Width | 1.422 INCHES MINIMUM AND |
| ABMK | Overall Width | 1.454 INCHES MAXIMUM |
| AEBW | Center To Center Distance Between Mounting Facilities Parallel To Height | 1.125 INCHES NOMINAL |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.125 INCHES NOMINAL |
| AFQK | Distance From Mounting Shoulder To Front Face | 0.462 INCHES MINIMUM AND |
| AFQK | Distance From Mounting Shoulder To Front Face | 0.472 INCHES MAXIMUM |
| AEBV | Unthreaded Mounting Hole Diameter | 0.145 INCHES MINIMUM AND |
| AEBV | Unthreaded Mounting Hole Diameter | 0.155 INCHES MAXIMUM |
| AFRV | Connector Locking Method | BAYONET PIN |
| AFRW | Connector Cable Strain Relief Method | POTTING TYPE |
| AFQJ | Cable Entrance Diameter | 0.798 INCHES MINIMUM |
| AFRT | Shell Type | POTTING |
| CSPT | Shell Material | ALUMINUM ALLOY |
| CSWM | Shell Surface Treatment | CADMIUM AND |
| CSWM | Shell Surface Treatment | CHROMATE |
| AFRN | Polarization Method | KEYWAY OR MULTIPLE KEYWAY |
| AFRP | Insert Position In Deg | 60.0 |
| AFQW | Mating End Quantity | 1 |
| AFQX | Contact Position Arrangement Style | 16-26 SINGLE MATING END |
| CQZG | Insert Material | RUBBER SINGLE MATING END |
| CXCG | Included Contact Quantity | 26 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFQZ | Contact Removability | REMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| CXCL | Included Contact Type | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRC | Contact Maximum Current Rating In Amps | 7.5 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRD | Contact Maximum Ac Voltage Rating In Volts | 500.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRE | Contact Maximum Dc Voltage Rating In Volts | 700.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| CQTZ | Contact Material | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
| CQYH | Contact Surface Treatment | GOLD AND |
| CQYH | Contact Surface Treatment | SILVER SINGLE MATING END SINGLE CONTACT GROUPING |
| CSCF | Terminal Type | CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
| CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| ADZC | Environmental Protection | MOISTURE RESISTANT |
| ZZZK | Specification/Standard Data | 72314-1079-844 MANUFACTURERS SPECIFICATION CONTROL |
| PRMT | Precious Material | GOLD AND |
| PRMT | Precious Material | SILVER |
| PMWT | Precious Material And Weight | 0.026 GOLD GRAINS, TROY OR |
| PMWT | Precious Material And Weight | 0.026 SILVER GRAINS, TROY AND |
| PMWT | Precious Material And Weight | 0.026 SILVER GRAINS, TROY |
| PMLC | Precious Material And Location | CONTACT SURFACES GOLD AND |
| PMLC | Precious Material And Location | CONTACT SURFACES SILVER |