| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| MS3108R32-13P | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5935 | 008546501 | A039B0 | 01938 | X | 4 | 9 | A | P | A | G | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains gold.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A918 | A196 | 0 | 0 | Z | CD | 1 Nov 2005 | ||||||||||||||||||||||||
| N9BN | 0 | 0 | Z | GH | HD | 1 Nov 2005 | ||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | TX | 0 | 8 Oct 1965 |
An item authorized for procurement that has not yet been subject to item standardization.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKFA | Distance From Centerline To Cable End | 2.594 INCHES MAXIMUM |
| ADMW | Body Angle In Deg | 90.0 |
| AFQJ | Cable Entrance Diameter | 1.156 INCHES MAXIMUM |
| AFRV | Connector Locking Method | INTERNALLY THREADED COUPLING RING |
| AFRW | Connector Cable Strain Relief Method | CABLE CLAMP |
| AFRD | Contact Maximum Ac Voltage Rating In Volts | 900.0 SINGLE MATING END ALL CONTACT GROUPINGS |
| AFRC | Contact Maximum Current Rating In Amps | 22.0 SINGLE MATING END 2ND CONTACT GROUPING |
| AFQX | Contact Position Arrangement Style | 32-13 SINGLE MATING END |
| AFQZ | Contact Removability | NONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
| AFRC | Contact Maximum Current Rating In Amps | 41.0 SINGLE MATING END 1ST CONTACT GROUPING |
| AFRE | Contact Maximum Dc Voltage Rating In Volts | 1250.0 SINGLE MATING END ALL CONTACT GROUPINGS |
| CQYH | Contact Surface Treatment | GOLD SINGLE MATING END ALL CONTACT GROUPINGS AND SILVER SINGLE MATING END ALL CONTACT GROUPINGS |
| ADZC | Environmental Protection | MOISTURE RESISTANT AND SALT WATER RESISTANT AND VIBRATION RESISTANT |
| AAQL | Body Style | ANGLE SHAPE W/CABLE CLAMP |
| AFQW | Mating End Quantity | 1 |
| CQJX | Nominal Thread Size | 2.000 INCHES |
| AKMG | Nominal Thread Length | 0.594 INCHES |
| CXCG | Included Contact Quantity | 18 SINGLE MATING END 2ND CONTACT GROUPING |
| CXCG | Included Contact Quantity | 5 SINGLE MATING END 1ST CONTACT GROUPING |
| CXCL | Included Contact Type | ROUND PIN SINGLE MATING END ALL CONTACT GROUPINGS |
| AFRP | Insert Position In Deg | 0.0 |
| AFRN | Polarization Method | KEY, MULTIPLE KEY GROOVE |
| PMLC | Precious Material And Location | CONTACT SURFACES GOLD AND CONTACT SURFACES SILVER |
| PMWT | Precious Material And Weight | 0.043 GOLD GRAINS, TROY AND 0.043 SILVER GRAINS, TROY |
| PRMT | Precious Material | GOLD AND SILVER |
| CTBC | Shell Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE |
| CSWM | Shell Surface Treatment | CADMIUM |
| AFRT | Shell Type | SOLID |
| CSPT | Shell Material | ALUMINUM ALLOY |
| ADAV | Overall Diameter | 2.219 INCHES MAXIMUM |
| ZZZK | Specification/Standard Data | 81349-MIL-C-5015 GOVERNMENT SPECIFICATION |
| CQTM | Terminal Location | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
| CSCF | Terminal Type | SOLDER WELL SINGLE MATING END ALL CONTACT GROUPINGS |
| TEST | Test Data Document | 81349-MIL-C-5015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| AAJD | Thread Class | 2B |
| AAJF | Thread Direction | RIGHT-HAND |
| THSD | Thread Series Designator | UNS |
| CMLP | Thread Quantity Per Inch | 18 |
| AFQR | Threaded Device Type | COUPLING FACILITY |