| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| BFR22-2P1 | 3 - Design Control Reference | 2 - Production Item | ITT CORPORATION | 71468 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5935 | 008800283 | A039B0 | 15093 | X | 1 | A | P | A | S | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains silver.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZZ | ||||||||||||||||||||||||||||||
| A918 | 3 | L | Z | CD | 1 Nov 2005 | |||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 72D | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AFQK | Distance From Mounting Shoulder To Front Face | 1.234 INCHES MAXIMUM |
| CXCJ | Bushing Accommodation Hole Shape | ROUND |
| AFRV | Connector Locking Method | EXTERNALLY THREADED SHELL |
| CQTZ | Contact Material | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRD | Contact Maximum Ac Voltage Rating In Volts | 900.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFQZ | Contact Removability | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRC | Contact Maximum Current Rating In Amps | 73.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRE | Contact Maximum Dc Voltage Rating In Volts | 1250.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFQX | Contact Position Arrangement Style | 22-2 SINGLE MATING END |
| CQYH | Contact Surface Treatment | SILVER SINGLE MATING END SINGLE CONTACT GROUPING |
| ADZC | Environmental Protection | SALT WATER RESISTANT |
| AAQL | Body Style | STRAIGHT SHAPE THREADED |
| AFQW | Mating End Quantity | 1 |
| AFQQ | Mounting Facility Thickness | 0.197 INCHES MAXIMUM |
| CQJX | Nominal Thread Size | 1.375 INCHES AND 1.375 INCHES |
| CXCL | Included Contact Type | ROUND PIN SINGLE MATING END SINGLE CONTACT GROUPING |
| CXCG | Included Contact Quantity | 3 SINGLE MATING END SINGLE CONTACT GROUPING |
| CQZG | Insert Material | RUBBER SINGLE MATING END |
| AFRP | Insert Position In Deg | 0.0 |
| AFRN | Polarization Method | KEYWAY OR MULTIPLE KEYWAY |
| PMLC | Precious Material And Location | CONTACT SURFACES SILVER |
| PMWT | Precious Material And Weight | 0.015 SILVER GRAINS, TROY |
| PRMT | Precious Material | SILVER |
| CSPT | Shell Material | ALUMINUM ALLOY |
| CSWM | Shell Surface Treatment | ANODIZE |
| AFRT | Shell Type | SOLID |
| ADAV | Overall Diameter | 1.948 INCHES MAXIMUM |
| ABHP | Overall Length | 1.515 INCHES MAXIMUM |
| CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| CSCF | Terminal Type | SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING |
| AAJD | Thread Class | 2A AND 2A |
| AAJF | Thread Direction | RIGHT-HAND AND RIGHT-HAND |
| THSD | Thread Series Designator | UNEF AND UNEF |
| CMLP | Thread Quantity Per Inch | 18 AND 18 |
| AFQR | Threaded Device Type | COUPLING FACILITY AND MOUNTING BUSHING |