5935-01-012-9814

CONNECTOR,PLUG,ELECTRICAL


5935-01-012-9814 (5935010129814, 010129814)
Part Numbers (2 listings): 4004295-289 | JT06RE-24-4PD(SR) |
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 20 Nov 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-01-012-9814 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
4004295-2893 - Design Control Reference2 - Production ItemHONEYWELL INTERNATIONAL INC.  07187    CAGE 07187  
JT06RE-24-4PD(SR)5 - Replaced / Discontinued2 - Production ItemAMPHENOL CORPORATION  77820    CAGE 77820  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5935-01-012-9814 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935010129814A039B001938X1APG20 Nov 1975
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

010129814

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-01-012-9814

A039B0

Federal Item Identification Guide (FIIG_4065)

01938

Item Naming Code (INC_4080)

20 Nov 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5935-01-012-9814 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Apr 1991
ZR011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5935-01-012-9814 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1321TXD4004295-289  07187   CAGE/07187
52ETXJT06RE-24-4PD(SR)  77820   CAGE/77820
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-01-012-9814 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX029 Aug 1980
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Aug 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-01-012-9814 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TXP658Z5AHZW061680Z34570ELEC-WIRING-PLUGS-ETC1
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-01-012-9814 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length1.938 INCHES MAXIMUM
AFQJCable Entrance Diameter0.775 INCHES MINIMUM AND 0.810 INCHES MAXIMUM
AFRWConnector Cable Strain Relief MethodCABLE CLAMP
AFRVConnector Locking MethodBAYONET LATCH
CQTZContact MaterialCOPPER ALLOY SINGLE MATING END ALL CONTACT GROUPINGS
AFRDContact Maximum Ac Voltage Rating In Volts600.0 SINGLE MATING END ALL CONTACT GROUPINGS
AFQXContact Position Arrangement Style24-4 SINGLE MATING END
AFQZContact RemovabilityREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS
AFREContact Maximum Dc Voltage Rating In Volts850.0 SINGLE MATING END ALL CONTACT GROUPINGS
CRBJContact Surface Treatment Document And ClassificationMIL-G-45204 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END ALL CONTACT GROUPINGS
CQYHContact Surface TreatmentGOLD SINGLE MATING END ALL CONTACT GROUPINGS
ADZCEnvironmental ProtectionMOISTURE RESISTANT
AAQLBody StyleSTRAIGHT SHAPE, INTERNAL COUPLING W/STRAIN RELIEF
AFQWMating End Quantity1
AWTNOperating Temp Rating-65.0 DEG CELSIUS MINIMUM AND 200.0 DEG CELSIUS MAXIMUM
CXCGIncluded Contact Quantity48 SINGLE MATING END 2ND CONTACT GROUPING
CXCGIncluded Contact Quantity8 SINGLE MATING END 1ST CONTACT GROUPING
CXCLIncluded Contact TypeROUND PIN SINGLE MATING END ALL CONTACT GROUPINGS
CQZGInsert MaterialPLASTIC EPOXY SINGLE MATING END AND GLASS FIBER SINGLE MATING END
AFRPInsert Position In Deg115.0
AFRNPolarization MethodKEYWAY OR MULTIPLE KEYWAY
PMLCPrecious Material And LocationCONTACT SURFACES GOLD
PMWTPrecious Material And Weight0.056 GOLD GRAINS, TROY
PRMTPrecious MaterialGOLD
CSPTShell MaterialALUMINUM ALLOY
CSWMShell Surface TreatmentCADMIUM AND NICKEL
AFRTShell TypeSOLID
CTBCShell Surface Treatment Document And ClassificationQQ-P-416 FED SPEC 1ST TREATMENT RESPONSE AND QQ-N-290,CLASS 2 FED SPEC 2ND TREATMENT RESPONSE
ADAVOverall Diameter1.750 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END ALL CONTACT GROUPINGS
CSCFTerminal TypeCRIMP SINGLE MATING END ALL CONTACT GROUPINGS


Back to Top