Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
NAS706T4 | 3 - Design Control Reference | 2 - Production Item | NATIONAL AEROSPACE STANDARDS | 80205 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 000568303 | A006B0 | 34672 | X | 1 | A | N | A | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 27 Dec 1965 | 5940009260028 | 2 Mar 1971 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
DLA Aviation, Richmond, VA 23297 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | NONTUBULAR ROUND |
AAJT | Overall Height | 0.813 INCHES |
AAJW | Overall Diameter | 0.250 INCHES |
CSZG | First End Terminal Length | 0.315 INCHES |
CSZQ | Second End Terminal Length | 0.311 INCHES |
CSFJ | Conductor Accommodation Type | DOUBLE TURRET ALL ENDS |
AALA | Largest Diameter | 0.145 INCHES SINGLE END |
AALD | Turret Minor Diameter | 0.065 INCHES ALL ENDS |
AALX | Mounting Method Style | SWAGE |
AAMU | Minor Bushing Length | 0.156 INCHES |
AAMX | Swage Depth | 0.062 INCHES |
AAMZ | Swage Outside Diameter | 0.250 INCHES |
AALV | Electrical Insulation Feature | UNINSULATED |
MATT | Material | COPPER ALLOY CONDUCTOR ACCOMMODATION |
MDCL | Material Document And Classification | QQ-B-626,1/2 H FED SPEC SINGLE MATERIAL RESPONSE CONDUCTOR ACCOMMODATION |
SFTT | Surface Treatment | TIN CONDUCTOR ACCOMMODATION SINGLE LAYER |
SFTT | Surface Treatment | TIN MOUNTING FACILITY SINGLE LAYER |
STDC | Surface Treatment Document And Classification | MIL-T-10727,TY 1 MIL SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SINGLE LAYER |
STDC | Surface Treatment Document And Classification | MIL-T-10727,TY 1 MIL SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SINGLE LAYER |