Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
1001425 | 3 - Design Control Reference | 9 - No Longer Used | MONMOUTH INDUSTRIES INC | 74082 | |
MEB1001425 | 5 - Replaced / Discontinued | 9 - No Longer Used | MONMOUTH INDUSTRIES INC | 74082 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 001435463 | A011B0 | 00404 | X | 4 | 9 | A | N | A | 0 | 18 Oct 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
N9BG | N9GD | 2 | G | Z | HD | HD | 1 Aug 2004 | |||||||||||||||||||||||
WP01 | 1 Nov 2004 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 1 | HH | D | 1001425 | 74082 | |||||
3 | 5 | 9 | 1 | HH | B | MEB1001425 | 74082 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Navy ICP, Mechanicsburg, PA 17055-0788
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HH | 72D | Z | 9 | A | H | Z | W | 061045 | Z | 34580 | BOARDS-PRINTED-CIRCUIT-ELEC |
Navy ICP, Mechanicsburg, PA 17055-0788
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABDW | Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole | 0.313 INCHES |
ABDX | Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility | 0.250 INCHES |
ABCX | Board Construction | SOLID CONSTRUCTION |
ABGN | Board Overall Length | 7.000 INCHES |
ABGP | Board Overall Width | 1.750 INCHES |
ABGT | Board Thickness | 0.125 INCHES |
AAQL | Body Style | STRIP TYPE |
ABDU | Center To Center Distance Between Mounting Facilities Parallel To Length | 6.500 INCHES |
ABDV | Center To Center Distance Between Mounting Facilities Parallel To Width | 1.125 INCHES |
ABCU | Distance Between Terminal Row Centers | 1.125 INCHES |
CQCW | Feedthru Connection End Type | 434 BOTH ENDS SINGLE COMBINATION |
CRZR | Feedthru Terminal Quantity | 26 SINGLE COMBINATION |
MATT | Material | GLASS FIBER BOARD AND PLASTIC EPOXY BOARD |
AAMA | Mounting Hole Diameter | 0.156 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CSCS | Nonfeedthru Terminal Quantity | 17 SINGLE |
CRNL | Nonfeedthru Terminal Type | 434 SINGLE |
MDCL | Material Document And Classification | MIL-P-18177,TYPE GEE MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
MARK | Special Markings | TERMINALS ON TOP OF BOARD MARKED R201,CR201,20,CR203,CR204,CR202,40,CR205,15,CR206,R215,R214,35,R202,R203,10,R213,R212,R211,30,R210,R208,5,R209,R206,R207,25,R205,1,R204,TERMINALS ON BOTTOM OF BOARD MARKED 43,20,40,17,37,14,11,32,29,6,3,23,BOARD MARKED TB210 |
STDC | Surface Treatment Document And Classification | MIL-F-14072,-221 MIL SPEC SINGLE TREATMENT RESPONSE TERMINALS |
SFTT | Surface Treatment | SOLDER TERMINALS |
ABDB | Terminal Facility Quantity | 1 |
CWLN | Terminal Design | VERTICAL FEEDTHRU |
CWLG | Terminal Pattern Arrangement | MULTI-ROW |
ABCS | Terminal Row Quantity | 2 |