Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
50SL542-499 | 3 - Design Control Reference | 2 - Production Item | U S TERMINALS INC | 12615 | ![]() |
FT25M1171 | 3 - Design Control Reference | 2 - Production Item | ITT CANNON RF PRODUCTS | 98291 | ![]() |
030621-0001 | 3 - Design Control Reference | 2 - Production Item | THALES DEFENSE & SECURITY, INC. | 65597 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 001776731 | A006B0 | 34672 | X | 1 | A | N | S | 25 Jun 1969 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 4 | CX | D | 50SL542-499 | 12615 | ![]() | ||||
3 | 3 | 2 | 1 | CX | D | 030621-0001 | 65597 | ![]() | ||||
3 | 3 | 2 | 4 | CX | D | FT25M1171 | 98291 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 24 Feb 1983 | 5940007174481 | 23 Feb 1983 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 658 | Z | 9 | A | H | Z | P | 061260 | X | 35180 | CABLE-TERMINALS-BOXES-HOUSINGS-ETC |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPA | Dry Flashover Voltage Rating In Volts | 4200.0 |
AALV | Electrical Insulation Feature | INSULATING MOUNTING BUSHING |
AGTA | Basic Shape Style | NONTUBULAR ROUND |
CSFJ | Conductor Accommodation Type | PIN ALL ENDS |
CSZG | First End Terminal Length | 0.200 INCHES |
AAPC | Identification Code Color | WHITE |
MATT | Material | COPPER ALLOY CONDUCTOR ACCOMMODATION |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE INSULATION |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE MOUNTING FACILITY |
AAMS | Minor Bushing Diameter | 0.132 INCHES |
AAMU | Minor Bushing Length | 0.130 INCHES |
AALX | Mounting Method Style | TWO-PIECE PRESS FIT |
AAJW | Overall Diameter | 0.172 INCHES |
AALA | Largest Diameter | 0.040 INCHES SINGLE END |
AAMV | Major Bushing Length | 0.050 INCHES |
AAMT | Major Bushing Diameter | 0.172 INCHES |
PMLC | Precious Material And Location | CONDUCTOR ACCOMMODATION FIRST LAYER SILVER AND CONDUCTOR ACCOMMODATION SECOND LAYER GOLD |
PMWT | Precious Material And Weight | 0.040 SILVER GRAINS, TROY AND 0.040 GOLD GRAINS, TROY |
PRMT | Precious Material | SILVER AND GOLD |
CSZQ | Second End Terminal Length | 0.200 INCHES |
AAJT | Overall Height | 0.565 INCHES |
SFTT | Surface Treatment | GOLD CONDUCTOR ACCOMMODATION SECOND LAYER |
SFTT | Surface Treatment | SILVER CONDUCTOR ACCOMMODATION FIRST LAYER |