5940-00-180-7996

TERMINAL BOARD


5940-00-180-7996 (5940001807996, 001807996)
Part Number (1 listing): 211542
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 10 Apr 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-180-7996 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2115423 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  92755    CAGE 92755  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-180-7996 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940001807996A011B000404XKANS10 Apr 1970
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

001807996

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-180-7996

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

10 Apr 1970

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-180-7996 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZP011 Apr 1991
YA011 Aug 2000
DGX1DCX13HCX1 Aug 2004
ZW011 Nov 2005
YF011 Dec 2014
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

CX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG C - REFERENCE NUMBER | NSN 5940-00-180-7996 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321CXD211542  92755   CAGE/92755
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-180-7996 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-180-7996 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX72DZ9AHZW061045Z34580BOARDS-PRINTED-CIRCUIT-ELEC
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061045

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

BOARDS-PRINTED-CIRCUIT-ELEC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5940-00-180-7996 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSVU1EA0
DSSMSYU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-180-7996 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABCXBoard ConstructionSOLID CONSTRUCTION
ABGNBoard Overall Length3.750 INCHES
ABGPBoard Overall Width2.500 INCHES
ABGTBoard Thickness0.090 INCHES
MATTMaterialGLASS FIBER BOARD AND PLASTIC EPOXY BOARD
AXHRMounting Facility Type And Quantity1 FRICTION
AAMAMounting Hole Diameter0.093 INCHES
CSCSNonfeedthru Terminal Quantity23 SINGLE
CRNLNonfeedthru Terminal Type439 SECOND
CRNLNonfeedthru Terminal Type434 FIRST
MDCLMaterial Document And ClassificationMIL-P-18177,TYPE GEB MIL SPEC SINGLE MATERIAL RESPONSE BOARD
PMLCPrecious Material And LocationTERMINALS SILVER
PRMTPrecious MaterialSILVER
MARKSpecial MarkingsE100,R100 THRU R108,1 THRU 19
AAQLBody Style
CWLNTerminal DesignNONFEEDTHRU
CWLGTerminal Pattern ArrangementRANDOM


Back to Top
Back to Top