5940-00-193-6911

TERMINAL BOARD


5940-00-193-6911 (5940001936911, 001936911)
Part Numbers (5 listings): VT0206L | SCB36294 | VT0206 | AA233559 | GSA1263 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-193-6911 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
VT0206L3 - Design Control Reference9 - No Longer UsedLEWYT CORP  36004      
SCB362945 - Replaced / Discontinued2 - Production ItemUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
VT02065 - Replaced / Discontinued2 - Production ItemRAULAND-BORG CORPORATION  3E191    CAGE 3E191  
AA2335595 - Replaced / Discontinued2 - Production ItemNAVCOM DEFENSE ELECTRONICS, INC.  57057    CAGE 57057  
GSA12635 - Replaced / Discontinued9 - No Longer UsedTELEKING CORP  94321      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-193-6911 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940001936911A011B000404XM9ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

001936911

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-193-6911

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-193-6911 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZS011 Apr 1991
ZU011 Apr 1991
WB011 Feb 2005
ZW011 Oct 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5940-00-193-6911 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
525CXAA233559  57057   CAGE/57057
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-193-6911 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX07 Feb 1975
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-193-6911 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-193-6911 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABDWDistance From Bottom Edge Of Terminal Board To Center Of Mounting Hole0.188 INCHES
ABDXDistance From Left Edge Of Terminal Board To Center Of First Mounting Facility0.188 INCHES
ABCXBoard ConstructionSOLID CONSTRUCTION
ABGNBoard Overall Length1.688 INCHES
ABGPBoard Overall Width1.000 INCHES
ABGTBoard Thickness0.062 INCHES
AAQLBody StyleSTRIP TYPE
ABDUCenter To Center Distance Between Mounting Facilities Parallel To Length0.625 INCHES
ABDVCenter To Center Distance Between Mounting Facilities Parallel To Width0.625 INCHES
ABCUDistance Between Terminal Row Centers0.312 INCHES
MATTMaterialPLASTIC PHENOLIC BOARD AND PAPER BOARD
CDTDMounting Facility Thread Series DesignatorUNC
AXHRMounting Facility Type And Quantity3 THREADED INSERT
CSCSNonfeedthru Terminal Quantity6 SINGLE
CRNLNonfeedthru Terminal Type583 SINGLE
MDCLMaterial Document And ClassificationL-P-513,TYPE PBE FED SPEC SINGLE MATERIAL RESPONSE BOARD
FEATSpecial FeaturesTWO MOUNTING INSERTS LOCATED ON LEFT WIDTH EDGE. ONE MOUNTING INSERT CENTRALLY LOCATED ON CENTER LINE 0.188 IN. FROM TOP OUTSIDE EDGE ALONG LENGTH
MARKSpecial MarkingsR101 R121 C104
STDCSurface Treatment Document And ClassificationMIL-T-10727,TYPE 2 MIL SPEC SINGLE TREATMENT RESPONSE TERMINALS
SFTTSurface TreatmentTIN TERMINALS
CWLNTerminal DesignNONFEEDTHRU
CWLGTerminal Pattern ArrangementMULTI-ROW
ABCSTerminal Row Quantity3


Back to Top