5940-00-201-9552

TERMINAL BOARD


5940-00-201-9552 (5940002019552, 002019552)
Part Number (1 listing): 410777
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-201-9552 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
4107773 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-201-9552 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940002019552A011B000404XKANG1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

002019552

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-201-9552

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-201-9552 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-201-9552 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX029 Mar 1973
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Mar 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-201-9552 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-201-9552 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABDWDistance From Bottom Edge Of Terminal Board To Center Of Mounting Hole1.200 INCHES
ABDXDistance From Left Edge Of Terminal Board To Center Of First Mounting Facility0.190 INCHES
ABCXBoard ConstructionSOLID CONSTRUCTION
ABGNBoard Overall Length7.000 INCHES
ABGPBoard Overall Width3.380 INCHES
ABGTBoard Thickness0.094 INCHES
AAQLBody StyleSTRIP TYPE
ABDUCenter To Center Distance Between Mounting Facilities Parallel To Length3.060 INCHES
ABDVCenter To Center Distance Between Mounting Facilities Parallel To Width1.670 INCHES
CQCWFeedthru Connection End Type434 BOTH ENDS SINGLE COMBINATION
CRZRFeedthru Terminal Quantity91 SINGLE COMBINATION
MATTMaterialCOPPER ALLOY TERMINALS
MATTMaterialPLASTIC BOARD
AXHRMounting Facility Type And Quantity6 UNTHREADED HOLE
AAMAMounting Hole Diameter0.146 INCHES
PMLCPrecious Material And LocationTERMINAL GOLD
PMWTPrecious Material And Weight0.040 GOLD GRAINS, TROY
PRMTPrecious MaterialGOLD
STDCSurface Treatment Document And ClassificationMIL-G-45204,TYPE 1,CLASS 1 MIL SPEC SINGLE TREATMENT RESPONSE TERMINALS
SFTTSurface TreatmentGOLD TERMINALS
CWLNTerminal DesignFEEDTHRU
ABDBTerminal Facility Quantity3
CWLGTerminal Pattern ArrangementRANDOM


Back to Top
Back to Top