5940-00-491-5436

TERMINAL,LUG


5940-00-491-5436 (5940004915436, 004915436)
Part Number (1 listing): 0N171045
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 14 Mar 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-491-5436 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0N1710453 - Design Control Reference2 - Production ItemNATIONAL SECURITY AGENCY  98230    CAGE 98230  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-491-5436 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940004915436A006B000746XM3ANA014 Mar 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

004915436

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-491-5436

A006B0

Federal Item Identification Guide (FIIG_4065)

00746

Item Naming Code (INC_4080)

14 Mar 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-491-5436 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
S0191 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5940-00-491-5436 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3322XND0N171045  98230   CAGE/98230
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

XN

Reference Number Action Activity Code (RNAAC_2900)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-491-5436 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
0XP025 Jun 1974
Code Definitions

0

Item Standardization Code (ISC_2650)


Items under the specification control of Defense Threat Reduction Agency (DTRA) or National Security Agency (NSA).

XP

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


National Security Agency, Fort George G. Meade, MD 20755-6000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

25 Jun 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-491-5436 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XN
Code Definitions

XN

Originating Activity Code (ORIG_ACTY_CD_4210)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-491-5436 Submit RFQ
MRCDecoded RequirementClear Text Reply
CSXTDistance From Mounting Hole Center To Mounting End0.050 INCHES
AALVElectrical Insulation FeatureUNINSULATED
CSXSAngle20.0 DEGREES
AGTABasic Shape StyleSOLDER, ANGULAR
ADHVCenter To Center Distance Between Mounting Holes Along Length0.275 INCHES
CSFJConductor Accommodation TypeSLANT LUG W/TWO HOLES SINGLE END
MDCLMaterial Document And ClassificationQQ-C-576 FED SPEC SINGLE MATERIAL RESPONSE CONDUCTOR ACCOMMODATION
MATTMaterialCOPPER MOUNTING FACILITY
MATTMaterialCOPPER CONDUCTOR ACCOMMODATION
AAMKMounting Facility Thickness0.031 INCHES
AAMAMounting Hole Diameter0.040 INCHES
AALXMounting Method StyleSTRAIGHT TWO HOLE
AAMCMounting Tongue Width0.050 INCHES
AALBLargest Width0.040 INCHES SINGLE END
AAJUOverall Length0.375 INCHES
AAJVOverall Width0.050 INCHES
SFTTSurface TreatmentTIN OVERALL SINGLE LAYER
TESTTest Data Document98230-0N171045 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Back to Top