5940-00-535-3438

TERMINAL BOARD


5940-00-535-3438 (5940005353438, 005353438)
Part Number (1 listing): 8511637
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-535-3438 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
85116373 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-535-3438 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940005353438A011B000404XKANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

005353438

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-535-3438

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-535-3438 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
YB011 Sep 2008
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-535-3438 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX012 May 1979
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

12 May 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-535-3438 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-535-3438 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABDWDistance From Bottom Edge Of Terminal Board To Center Of Mounting Hole0.187 INCHES
ABDXDistance From Left Edge Of Terminal Board To Center Of First Mounting Facility1.500 INCHES
ABCXBoard ConstructionSOLID CONSTRUCTION
ABGNBoard Overall Length7.000 INCHES
ABGPBoard Overall Width2.000 INCHES
ABGTBoard Thickness0.093 INCHES
AAQLBody StyleSTRIP TYPE
ABDUCenter To Center Distance Between Mounting Facilities Parallel To Length4.125 INCHES
ABDVCenter To Center Distance Between Mounting Facilities Parallel To Width1.625 INCHES
ABCTCenter To Center Distance Between Terminals0.375 INCHES
ABCUDistance Between Terminal Row Centers1.625 INCHES
MATTMaterialPLASTIC PHENOLIC BOARD AND PAPER BOARD
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AAMAMounting Hole Diameter0.196 INCHES
CSCSNonfeedthru Terminal Quantity32 SINGLE
CRNLNonfeedthru Terminal Type442 SINGLE
MDCLMaterial Document And ClassificationL-P-513,TYPE PBE FED SPEC SINGLE MATERIAL RESPONSE BOARD
CQCZTerminal Connecting Link Quantity17 SINGLE
CSCRTerminal Connecting Link Type1 SINGLE
CWLNTerminal DesignLINKED NONFEEDTHRU
CWLGTerminal Pattern ArrangementMULTI-ROW
ABCSTerminal Row Quantity2