Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
450-35053 | 3 - Design Control Reference | 2 - Production Item | BAE SYSTEMS INFORMATION AND | 81413 | ![]() |
SFT86 | 3 - Design Control Reference | 2 - Production Item | ARMEL ELECTRONICS INC | 91663 | ![]() |
832752 | 5 - Replaced / Discontinued | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 56232 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 005390373 | A006B0 | 34672 | X | 4 | 3 | A | N | A | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
N9BG | N9GD | 1 | H | Z | HD | KE | 1 Aug 2004 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | G | 063330 | X | 34400 | ELECTRICAL-TERMINAL-TERMINAL-BLOCKS |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
125
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | NONTUBULAR HEX |
AAGW | Width Across Flats | 0.313 INCHES |
AAJT | Overall Height | 2.032 INCHES |
CSZG | First End Terminal Length | 0.157 INCHES |
CSZQ | Second End Terminal Length | 1.125 INCHES |
CSFJ | Conductor Accommodation Type | NAILHEAD FIRST END |
CSFJ | Conductor Accommodation Type | SINGLE TURRET SECOND END |
AALA | Largest Diameter | 0.109 INCHES ALL ENDS |
AALD | Turret Minor Diameter | 0.062 INCHES ALL ENDS |
AALX | Mounting Method Style | THREADED BUSHING |
AAMV | Major Bushing Length | 0.124 INCHES |
AANA | Threaded Bushing Width Across Flats | 0.313 INCHES |
ABET | Thread Length | 0.219 INCHES |
ATGD | Mounting Thread Series | UNF |
AAMP | Mounting Thread Diameter | 0.250 INCHES |
AALV | Electrical Insulation Feature | STANDOFF INSULATION |
AAPC | Identification Code Color | WHITE |
MATT | Material | COPPER ALLOY CONDUCTOR ACCOMMODATION |
MATT | Material | PLASTIC MELAMINE INSULATION |
MATT | Material | COPPER ALLOY MOUNTING FACILITY |
SFTT | Surface Treatment | SOLDER CONDUCTOR ACCOMMODATION SINGLE LAYER |
SFTT | Surface Treatment | CADMIUM MOUNTING FACILITY SINGLE LAYER |