5940-00-644-5351

TERMINAL,STUD


5940-00-644-5351 (5940006445351, 006445351)
Part Numbers (11 listings): 142-7-10 | 1930B | 6910-2 | 210-1028P1 | 8005-B-7.1 | 9955103 | B-1830-14-11.2 | 807-14 | 1246-11 | X1246B1-4 | 350-1246-11-07-00 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-644-5351 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
142-7-103 - Design Control Reference2 - Production ItemKEARFOTT CORPORATION  88818    CAGE 88818  
1930B3 - Design Control Reference2 - Production ItemGOE ENGINEERING CO INC  00866      
6910-23 - Design Control Reference2 - Production ItemLYN-TRON INC  05791      
210-1028P13 - Design Control Reference2 - Production ItemRAYTHEON CO  99687    CAGE 99687  
8005-B-7.13 - Design Control Reference2 - Production ItemLERCO DIV SPACE-LOK INC  52525      
99551035 - Replaced / Discontinued2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
B-1830-14-11.25 - Replaced / Discontinued9 - No Longer UsedLTA/D-CEMCO INC  21355      
807-145 - Replaced / Discontinued9 - No Longer UsedLTA/D-CEMCO INC  21355      
1246-115 - Replaced / Discontinued9 - No Longer UsedINTERCONNECTION PRODUCTS INC  71279    CAGE 71279  
X1246B1-45 - Replaced / Discontinued9 - No Longer UsedINTERCONNECTION PRODUCTS INC  71279    CAGE 71279  
350-1246-11-07-005 - Replaced / Discontinued9 - No Longer UsedINTERCONNECTION PRODUCTS INC  71279    CAGE 71279  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-644-5351 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940006445351A006B000887X43ANA1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

006445351

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-644-5351

A006B0

Federal Item Identification Guide (FIIG_4065)

00887

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-644-5351 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
N9BGNIGD1HZKEHDKE1 Aug 2004
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5940-00-644-5351 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4324CXD1930B  00866  
4324CXD6910-2  05791  
4324CXD8005-B-7.1  52525  
1325CXD142-7-10  88818   CAGE/88818
3325CXD210-1028P1  99687   CAGE/99687
3521CXD9955103  18876   CAGE/18876
4594CXB807-14  21355  
4594CXBB-1830-14-11.2  21355  
1594CXB1246-11  71279   CAGE/71279
4594CXB350-1246-11-07-00  71279   CAGE/71279
1594CXBX1246B1-4  71279   CAGE/71279
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-644-5351 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
598029 Apr 2010
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Apr 2010

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-644-5351 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5940-00-644-5351 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSVU0ZPG0
DNSMSYU0PG0
DSSMSYU0NPG0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-644-5351 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGTABasic Shape StyleTUBULAR, ROUND
AAEYTerminal Length0.109 INCHES
AAJTOverall Height0.359 INCHES
AAJWOverall Diameter0.250 INCHES
AAKBThru-Hole Diameter0.150 INCHES
CSFJConductor Accommodation TypeTHREADED INTERNAL SINGLE END
AALALargest Diameter0.250 INCHES SINGLE END
AALXMounting Method StyleSWAGE
AAMUMinor Bushing Length0.109 INCHES
AAMXSwage Depth0.109 INCHES
AAMZSwage Outside Diameter0.187 INCHES
AALVElectrical Insulation FeatureUNINSULATED
MATTMaterialCOPPER ALLOY CONDUCTOR ACCOMMODATION
MDCLMaterial Document And ClassificationQQ-B-626,1/2H FED SPEC SINGLE MATERIAL RESPONSE MOUNTING FACILITY
SFTTSurface TreatmentCADMIUM CONDUCTOR ACCOMMODATION SINGLE LAYER
SFTTSurface TreatmentCADMIUM MOUNTING FACILITY SINGLE LAYER
STDCSurface Treatment Document And ClassificationQQ-P-416,TY 2,CL2 FED SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SINGLE LAYER
STDCSurface Treatment Document And ClassificationQQ-P-416,TY2,CL 2 FED SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SINGLE LAYER


Back to Top
Back to Top