5940-00-680-9727

TERMINAL,FEEDTHRU


5940-00-680-9727 (5940006809727, 006809727)
Part Numbers (2 listings): 2012-1 | X2012 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

5940-00-915-6116

Replacement Date: 27 Dec 1965

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-680-9727 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2012-13 - Design Control Reference9 - No Longer UsedINTERCONNECTION PRODUCTS INC  71279    CAGE 71279  
X20125 - Replaced / Discontinued9 - No Longer UsedINTERCONNECTION PRODUCTS INC  71279    CAGE 71279  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-680-9727 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940006809727A006B034672XM9ANS1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

006809727

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-680-9727

A006B0

Federal Item Identification Guide (FIIG_4065)

34672

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-680-9727 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-680-9727 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3CX11CX027 Dec 1965 5940009156116 27 Dec 1965
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

27 Dec 1965

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5940-00-915-6116

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

27 Dec 1965

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-680-9727 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P658Z9AHZW063160Z35205SWITCH-BOXES-ELEC-ENCLOSURES1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063160

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35205

Uniform Freight Classification (UFC_CD_MODF_3040)

SWITCH-BOXES-ELEC-ENCLOSURES

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-680-9727 Submit RFQ
MRCDecoded RequirementClear Text Reply
AALVElectrical Insulation FeatureINSULATING MOUNTING BUSHING
AGTABasic Shape StyleNONTUBULAR HEX
CSFJConductor Accommodation TypeDOUBLE TURRET ALL ENDS
CSZGFirst End Terminal Length0.282 INCHES
MATTMaterialCERAMIC INSULATION
MATTMaterialCOPPER ALLOY CONDUCTOR ACCOMMODATION
MATTMaterialCOPPER ALLOY MOUNTING FACILITY
AAMSMinor Bushing Diameter0.344 INCHES
AAMUMinor Bushing Length0.375 INCHES
AALXMounting Method StylePRESS FIT
AALALargest Diameter0.080 INCHES ALL ENDS
AAMTMajor Bushing Diameter0.500 INCHES
AAMVMajor Bushing Length0.062 INCHES
PMLCPrecious Material And LocationCONDUCTOR ACCOMMODATION SILVER
PRMTPrecious MaterialSILVER
CSZQSecond End Terminal Length0.285 INCHES
AAJTOverall Height1.307 INCHES
AALDTurret Minor Diameter0.050 INCHES ALL ENDS
AAGWWidth Across Flats0.500 INCHES
SFTTSurface TreatmentSILVER CONDUCTOR ACCOMMODATION SINGLE LAYER
SFTTSurface TreatmentNICKEL MOUNTING FACILITY SINGLE LAYER


Back to Top
Back to Top