Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7050792P1 | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 03538 | ![]() |
7050792P1 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL ELECTRIC CO | 24446 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 008254734 | A006B0 | 00887 | X | 4 | 4 | A | N | S | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC | 1 |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAEY | Terminal Length | 0.061 INCHES |
AAGW | Width Across Flats | 0.140 INCHES |
AAJT | Overall Height | 0.093 INCHES |
CSFJ | Conductor Accommodation Type | SOLDER POT SINGLE END |
AALA | Largest Diameter | 0.093 INCHES SINGLE END |
AALL | Wire Hole Diameter | 0.024 INCHES SINGLE END |
AALX | Mounting Method Style | SWAGE |
AAMU | Minor Bushing Length | 0.061 INCHES |
AAMX | Swage Depth | 0.060 INCHES |
AAMZ | Swage Outside Diameter | 0.093 INCHES |
AALV | Electrical Insulation Feature | UNINSULATED |
MATT | Material | COPPER ALLOY 360 OVERALL EXCEPT INSULATION |
MDCL | Material Document And Classification | QQ-B-611,1/2H,CANC FED SPEC SINGLE MATERIAL RESPONSE OVERALL EXCEPT INSULATION |
SFTT | Surface Treatment | SILVER OVERALL EXCEPT INSULATION SINGLE LAYER |
CBBL | Features Provided | INSULATION PIERCING DEVICE |
FEAT | Special Features | BASIC SHAPE STYLE SINGLE ENDED NONTUBULAR |
PRMT | Precious Material | SILVER |
PMLC | Precious Material And Location | O/A EXCEPT INSULATION SILVER |