Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
RTMS12E | 3 - Design Control Reference | 2 - Production Item | ARMEL ELECTRONICS INC | 91663 | |
306-1087-000 | 3 - Design Control Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | |
2039A4G | 5 - Replaced / Discontinued | 9 - No Longer Used | ELECTRONIC MOLDING CORP | 17117 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 009049628 | A006B0 | 00887 | X | 1 | A | N | C | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains combination of two or more precious metals (silver, gold, platinum).
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Mar 1996 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
YW01 | 1 Aug 2000 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 5 | CX | D | 306-1087-000 | 13499 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 19 Oct 1976 | 5940002723709 | 17 Oct 1976 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | W | 095190 | Z | 49790 | HARDWARE--NOI |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
DLA Aviation, Richmond, VA 23297 ** No longer valid for input **
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | NONTUBULAR, HEX |
AAEY | Terminal Length | 0.250 INCHES |
AAGW | Width Across Flats | 0.250 INCHES |
AAJT | Overall Height | 0.844 INCHES |
CSFJ | Conductor Accommodation Type | PIN SINGLE END |
AALA | Largest Diameter | 0.078 INCHES SINGLE END |
AALX | Mounting Method Style | STUD |
ABET | Thread Length | 0.219 INCHES |
ATGD | Mounting Thread Series | UNC |
AAMP | Mounting Thread Diameter | 0.122 INCHES |
AALV | Electrical Insulation Feature | INSULATING SLEEVE |
AAPC | Identification Code Color | WHITE |
MATT | Material | COPPER ALLOY CONDUCTOR ACCOMMODATION |
MATT | Material | PLASTIC DIALLYL PHTHALATE INSULATION |
MATT | Material | COPPER ALLOY MOUNTING FACILITY |
SFTT | Surface Treatment | SILVER CONDUCTOR ACCOMMODATION FIRST LAYER |
SFTT | Surface Treatment | GOLD CONDUCTOR ACCOMMODATION SECOND LAYER |
SFTT | Surface Treatment | SILVER MOUNTING FACILITY FIRST LAYER |
SFTT | Surface Treatment | GOLD MOUNTING FACILITY SECOND LAYER |
AAPA | Dry Flashover Voltage Rating In Volts | 6000.0 |