Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS17157-7 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 009141839 | A006B0 | 00887 | X | 4 | 9 | A | N | V | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal type varies between manufacturers.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 28 Sep 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC | 1 |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AALV | Electrical Insulation Feature | UNINSULATED |
CSFJ | Conductor Accommodation Type | DOUBLE TURRET SINGLE END |
MDCL | Material Document And Classification | QQ-B-626,1/2H FED SPEC SINGLE MATERIAL RESPONSE OVERALL EXCEPT INSULATION |
MATT | Material | COPPER ALLOY 360 OVERALL EXCEPT INSULATION |
AAMU | Minor Bushing Length | 0.105 INCHES |
AALX | Mounting Method Style | SWAGE |
AALA | Largest Diameter | 0.093 INCHES SINGLE END |
PMLC | Precious Material And Location | CONDUCTOR ACCOMMODATION,FIRST LAYER AND MTG FACILITY,SECOND LAYER SILVER AND CONDUCTOR ACCOMMODATION,SECOND LAYER AND MTG FACILITY FIRST LAYER GOLD |
PRMT | Precious Material | SILVER AND GOLD |
AAJW | Overall Diameter | 0.187 INCHES |
AAJT | Overall Height | 0.573 INCHES |
FEAT | Special Features | DOUBLE ENDED NONTUBULAR SHAPE STYLE |
AALD | Turret Minor Diameter | 0.047 INCHES SINGLE END |
STDC | Surface Treatment Document And Classification | MIL-S-13282,GR A MIL SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SECOND LAYER |
STDC | Surface Treatment Document And Classification | MIL-G-45204,TY 2 MIL SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SECOND LAYER |
STDC | Surface Treatment Document And Classification | MIL-G-45204,TY 2 MIL SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY FIRST LAYER |
STDC | Surface Treatment Document And Classification | QQ-S-365,TY 2 FED SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION FIRST LAYER |
SFTT | Surface Treatment | GOLD CONDUCTOR ACCOMMODATION SECOND LAYER |
SFTT | Surface Treatment | GOLD MOUNTING FACILITY FIRST LAYER |
AAMZ | Swage Outside Diameter | 0.156 INCHES |
SFTT | Surface Treatment | SILVER CONDUCTOR ACCOMMODATION FIRST LAYER |
SFTT | Surface Treatment | SILVER MOUNTING FACILITY SECOND LAYER |