5940-00-923-8121

TERMINAL BOARD


5940-00-923-8121 (5940009238121, 009238121)
Part Numbers (2 listings): 10067948-6 | 625A869ANP1 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1960

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-923-8121 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
10067948-63 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
625A869ANP15 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  03510      
625A869ANP15 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-923-8121 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940009238121A011B000404X1ANU1 Jan 1960
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

009238121

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-923-8121

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

1 Jan 1960

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-923-8121 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Aug 1995
YK011 Feb 2015
ZF011 May 2015
YD011 Sep 2016
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-923-8121 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX118 Sep 1967
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

18 Sep 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-923-8121 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
W772Z9ABZW156600Z77670PLASTIC-RUBBER-ARTICLE-VIZ-
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


W

Less Than Carload (LCL_CD_2760)


Rating Variable

772

Water Commodity Code (WRT_CMDTY_CD_9275)


Food service equipment, (MKT), Field Ranges, Vacuum Cans, Beverage Containers, ETC

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

156600

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

77670

Uniform Freight Classification (UFC_CD_MODF_3040)

PLASTIC-RUBBER-ARTICLE-VIZ-

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-923-8121 Submit RFQ
MRCDecoded RequirementClear Text Reply
MATTMaterialPLASTIC BOARD
MATTMaterialCOPPER ALLOY TERMINALS
SFTTSurface TreatmentNICKEL TERMINALS
AAQLBody StyleBARRIER TYPE
ABGNBoard Overall Length1.406 INCHES
ABGPBoard Overall Width0.562 INCHES
ABGQBoard Overall Height0.406 INCHES
ABGRBoard Height Excluding Terminals0.406 INCHES
ABGSBase Thickness0.250 INCHES
CWLGTerminal Pattern ArrangementSINGLE ROW
ABCSTerminal Row Quantity1
ABCTCenter To Center Distance Between Terminals0.375 INCHES
CWLNTerminal DesignNONFEEDTHRU
CRNLNonfeedthru Terminal Type857 SINGLE
CSCSNonfeedthru Terminal Quantity2 SINGLE
ABCXBoard ConstructionHOLLOW CONSTRUCTION WITHOUT INSULATED STRIP
AXHRMounting Facility Type And Quantity2 UNTHREADED HOLE
ABDUCenter To Center Distance Between Mounting Facilities Parallel To Length1.125 INCHES
ABDWDistance From Bottom Edge Of Terminal Board To Center Of Mounting Hole0.281 INCHES
ABDXDistance From Left Edge Of Terminal Board To Center Of First Mounting Facility0.141 INCHES
AAMAMounting Hole Diameter0.156 INCHES


Back to Top