Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
GM3449-65GCTC | 3 - Design Control Reference | 2 - Production Item | STAFFALL INC. | 27494 | ![]() |
2033K | 5 - Replaced / Discontinued | 9 - No Longer Used | ELECTRONIC MOLDING CORP | 17117 | ![]() |
G272564-20 | D - Drawing Number Reference | 9 - No Longer Used | AMERICAN TELEPHONE AND TELEGRAPH CO | 64959 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 009358213 | A006B0 | 00887 | X | 4 | 3 | A | N | A | 31 May 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
N9BG | 3 | H | Z | HD | HD | 1 Aug 2004 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | CX | D | GM3449-65GCTC | 27494 | ![]() | ||||
3 | 5 | 9 | 1 | CX | B | 2033K | 17117 | ![]() | ||||
3 | D | 9 | A | CX | D | G272564-20 | 64959 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 72D | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | NONTUBULAR, HEX |
AAEY | Terminal Length | 0.250 INCHES |
AAGW | Width Across Flats | 0.250 INCHES |
AAJT | Overall Height | 0.844 INCHES |
CSFJ | Conductor Accommodation Type | PIN SINGLE END |
AALA | Largest Diameter | 0.078 INCHES SINGLE END |
AALX | Mounting Method Style | TAPPED HOLE |
ABET | Thread Length | 0.219 INCHES |
ATGD | Mounting Thread Series | UNC |
AAMP | Mounting Thread Diameter | 0.138 INCHES |
CGGK | Mounting Thread Quantity | 32 PER INCH |
AALV | Electrical Insulation Feature | STANDOFF INSULATION |
AAPC | Identification Code Color | WHITE |
MATT | Material | COPPER ALLOY CONDUCTOR ACCOMMODATION |
MDCL | Material Document And Classification | QQ-B-626,1/2 H FED SPEC SINGLE MATERIAL RESPONSE CONDUCTOR ACCOMMODATION |
SFTT | Surface Treatment | COPPER CONDUCTOR ACCOMMODATION FIRST LAYER |
SFTT | Surface Treatment | TIN CONDUCTOR ACCOMMODATION SECOND LAYER |
SFTT | Surface Treatment | COPPER MOUNTING FACILITY FIRST LAYER |
SFTT | Surface Treatment | TIN MOUNTING FACILITY SECOND LAYER |
STDC | Surface Treatment Document And Classification | MIL-C-14550 CL 3 MIL SPEC 1ST TREATMENT RESPONSE CONDUCTOR ACCOMMODATION FIRST LAYER |
STDC | Surface Treatment Document And Classification | MIL-T-10727,TY 1 MIL SPEC 2ND TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SECOND LAYER |
STDC | Surface Treatment Document And Classification | MIL-C-14550 CL 3 MIL SPEC 1ST TREATMENT RESPONSE MOUNTING FACILITY FIRST LAYER |
STDC | Surface Treatment Document And Classification | MIL-T-10727,TY 1 MIL SPEC 2ND TREATMENT RESPONSE MOUNTING FACILITY SECOND LAYER |