Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
602-JJ-Y-01 | 3 - Design Control Reference | 2 - Production Item | MARATHON SPECIAL PRODUCTS | 26405 | ![]() |
602JJY1 | 5 - Replaced / Discontinued | 9 - No Longer Used | DIALIGHT CORPORATION | 83330 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 009506229 | A011B0 | 00404 | X | 1 | A | N | A | 4 May 1966 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | DCX1 | 1 | G | CX | 1 Aug 2004 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Defense Supply Center Richmond, Richmond, VA 23297-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | CX | 602-JJ-Y-01 | 26405 | ![]() | ||||||
5 | 9 | 4 | CX | B | 602JJY1 | 83330 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 738 | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH-BOXES-ELEC-ENCLOSURES |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Computing Equipment, Computer Components, and Circuit Cards
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABDW | Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole | 0.188 INCHES |
ABDX | Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility | 0.203 INCHES |
ABGS | Base Thickness | 0.375 INCHES |
ABCX | Board Construction | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABGR | Board Height Excluding Terminals | 0.625 INCHES |
ABGQ | Board Overall Height | 1.125 INCHES |
ABGN | Board Overall Length | 1.531 INCHES |
ABGP | Board Overall Width | 1.312 INCHES |
AAQL | Body Style | BARRIER TYPE |
ABDU | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.125 INCHES |
ABDV | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.500 INCHES |
ABCT | Center To Center Distance Between Terminals | 0.562 INCHES |
AMPS | Current Rating In Amps | 30.0 |
AAPB | Dielectric Withstanding Voltage In Volts | 4.8 |
ABCU | Distance Between Terminal Row Centers | 0.500 INCHES |
CQCW | Feedthru Connection End Type | 857 FOURTH COMBINATION BOTH ENDS |
CQCW | Feedthru Connection End Type | F4 15TH MATERIAL RESPONSE BOTH ENDS |
CRZR | Feedthru Terminal Quantity | 1 SINGLE COMBINATION |
MDCL | Material Document And Classification | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
MATT | Material | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AAMA | Mounting Hole Diameter | 0.209 INCHES |
SFTT | Surface Treatment | NICKEL TERMINALS AND TIN TERMINALS |
CQCZ | Terminal Connecting Link Quantity | 1 SINGLE |
CSCR | Terminal Connecting Link Type | 2 SINGLE |
CWLN | Terminal Design | FEEDTHRU |
CWLG | Terminal Pattern Arrangement | SINGLE ROW |
ABCS | Terminal Row Quantity | 2 |