5940-00-958-3915

TERMINAL BOARD


5940-00-958-3915 (5940009583915, 009583915)
Part Numbers (5 listings): 9139028-7 | 6-141-3-4WFF | JN113162-206 | 601-JJ-06-3/4ST | 601H3-4ST6 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

5940-00-983-6084

Replacement Date: 28 Dec 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-00-958-3915 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
9139028-73 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
6-141-3-4WFF5 - Replaced / Discontinued2 - Production ItemCINCH CONNECTORS, INC.  71785    CAGE 71785  
JN113162-2065 - Replaced / Discontinued2 - Production ItemDIALIGHT CORPORATION  83330    CAGE 83330  
601-JJ-06-3/4ST5 - Replaced / Discontinued2 - Production ItemDIALIGHT CORPORATION  83330    CAGE 83330  
601H3-4ST65 - Replaced / Discontinued9 - No Longer UsedDIALIGHT CORPORATION  83330    CAGE 83330  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5940-00-958-3915 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940009583915A011B000404XKANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

009583915

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-00-958-3915

A011B0

Federal Item Identification Guide (FIIG_4065)

00404

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5940-00-958-3915 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
YB011 Feb 1994
ZW011 Nov 2005
ZR011 Dec 2007
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5940-00-958-3915 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
525CX601-JJ-06-3/4ST  83330   CAGE/83330
525CXJN113162-206  83330   CAGE/83330
595CXB601H3-4ST6  83330   CAGE/83330
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-00-958-3915 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3CX11CX028 Dec 1975 5940009836084 10 Aug 1986
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Dec 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5940-00-983-6084

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

10 Aug 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-00-958-3915 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
772Z9ABZZ000000X00000NO-NMFC-FREIGHT-DESCRIPTION
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


772

Water Commodity Code (WRT_CMDTY_CD_9275)


Food service equipment, (MKT), Field Ranges, Vacuum Cans, Beverage Containers, ETC

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

Z

Less Than Truckload (CLAS_RTNG_CD_2770)


No Rating

000000

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

00000

Uniform Freight Classification (UFC_CD_MODF_3040)

NO-NMFC-FREIGHT-DESCRIPTION

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-00-958-3915 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABDWDistance From Bottom Edge Of Terminal Board To Center Of Mounting Hole0.225 INCHES
ABDXDistance From Left Edge Of Terminal Board To Center Of First Mounting Facility0.156 INCHES
ABCXBoard ConstructionSOLID CONSTRUCTION
ABGRBoard Height Excluding Terminals1.125 INCHES
ABGQBoard Overall Height1.344 INCHES
ABGNBoard Overall Length3.375 INCHES
ABGTBoard Thickness0.500 INCHES
AAQLBody StyleSTRIP
ABDUCenter To Center Distance Between Mounting Facilities Parallel To Length3.062 INCHES
ABDVCenter To Center Distance Between Mounting Facilities Parallel To Width0.422 INCHES
MATTMaterialCOPPER ALLOY TERMINALS
MATTMaterialPLASTIC BOARD
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AAMAMounting Hole Diameter0.175 INCHES
CSCSNonfeedthru Terminal Quantity6 SINGLE
CRNLNonfeedthru Terminal Type193 SINGLE
SFTTSurface TreatmentSOLDER TERMINALS


Back to Top