5940-01-006-7148

TERMINAL,STUD


5940-01-006-7148 (5940010067148, 010067148)
Part Numbers (2 listings): 1481A-8-11 | 10275462 |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 22 Jul 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-01-006-7148 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1481A-8-113 - Design Control Reference2 - Production ItemWINCHESTER ELECTRONICS CORPORATION  81312    CAGE 81312  
102754625 - Replaced / Discontinued2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-01-006-7148 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940010067148A006B000887X43ANG22 Jul 1975
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

010067148

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-01-006-7148

A006B0

Federal Item Identification Guide (FIIG_4065)

00887

Item Naming Code (INC_4080)

22 Jul 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5940-01-006-7148 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
DGX1DCX11GCX1 Aug 2004
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.

CX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG C - REFERENCE NUMBER | NSN 5940-01-006-7148 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324CXD1481A-8-11  81312   CAGE/81312
1521CXD10275462  18876   CAGE/18876
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-01-006-7148 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX028 Feb 1982
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Feb 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-01-006-7148 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX72DZ9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5940-01-006-7148 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSVUAEA0
DSSMSVUANEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

A

Quantity Unit Pack (QUP_6106)


10

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-01-006-7148 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGTABasic Shape StyleNONTUBULAR, HEX
AAEYTerminal Length0.154 INCHES
AAGWWidth Across Flats0.188 INCHES
AAJTOverall Height0.420 INCHES
CSFJConductor Accommodation TypeDOUBLE TURRET SINGLE END
AALALargest Diameter0.062 INCHES SINGLE END
AALDTurret Minor Diameter0.031 INCHES SINGLE END
AALXMounting Method StyleTAPPED HOLE
ABETThread Length0.094 INCHES
ATGDMounting Thread SeriesUNC
AAMPMounting Thread Diameter0.112 INCHES
AALVElectrical Insulation FeatureSTANDOFF INSULATION
AAPCIdentification Code ColorWHITE
MATTMaterialALUMINA INSULATION
MATTMaterialCOPPER ALLOY OVERALL EXCEPT INSULATION
MDCLMaterial Document And ClassificationMIL-I-10,L624 MIL SPEC SINGLE MATERIAL RESPONSE INSULATION
MDCLMaterial Document And ClassificationQQ-B-626,COMP 22,1/2 H FED SPEC SINGLE MATERIAL RESPONSE OVERALL EXCEPT INSULATION
SFTTSurface TreatmentNICKEL CONDUCTOR ACCOMMODATION FIRST LAYER
SFTTSurface TreatmentGOLD CONDUCTOR ACCOMMODATION SECOND LAYER
SFTTSurface TreatmentCADMIUM MOUNTING FACILITY SINGLE LAYER
STDCSurface Treatment Document And ClassificationQQ-N-290,CLASS 1 FED SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION FIRST LAYER
STDCSurface Treatment Document And ClassificationMIL-G-45204,TYPE 1 OR 2 MIL SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SECOND LAYER
STDCSurface Treatment Document And ClassificationQQ-P-416,TYPE 1,CLASS 2 FED SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SINGLE LAYER
AAPADry Flashover Voltage Rating In Volts2200.0
PRMTPrecious MaterialGOLD
PMWTPrecious Material And Weight0.040 GOLD GRAINS, TROY
PMLCPrecious Material And LocationCONDUCTOR ACCOMMODATION OUTER LAYER GOLD


Back to Top
Back to Top