Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
13006-50 | 3 - Design Control Reference | 9 - No Longer Used | AXSYS TECHNOLOGIES INC | 13150 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5940 | 010407972 | A011B0 | 00404 | X | 4 | 6 | A | N | U | 4 Oct 1980 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G190 | 0 | 0 | C | 1 Apr 1991 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 4 | 75 | D | 13006-50 | 13150 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
GSA, FSS/FCSC Washington, DC 20406
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 21 Sep 1985 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
19 |
NASA - Langley Research Center, Stennis Space Center, MS 39529-6000
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABDW | Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole | 0.274 INCHES |
ABDX | Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility | 0.188 INCHES |
ABGS | Base Thickness | 0.313 INCHES |
ABCX | Board Construction | SOLID CONSTRUCTION |
ABGR | Board Height Excluding Terminals | 0.547 INCHES |
ABGQ | Board Overall Height | 0.953 INCHES |
ABGN | Board Overall Length | 3.438 INCHES |
ABGP | Board Overall Width | 0.734 INCHES |
AAQL | Body Style | BARRIER TYPE |
ABDU | Center To Center Distance Between Mounting Facilities Parallel To Length | 3.063 INCHES |
ABCT | Center To Center Distance Between Terminals | 0.438 INCHES |
AMPS | Current Rating In Amps | 20.0 |
CRZR | Feedthru Terminal Quantity | 6 SINGLE COMBINATION |
MATT | Material | COPPER ALLOY TERMINALS |
MATT | Material | PLASTIC PHENOLIC BOARD |
AAMA | Mounting Hole Diameter | 0.190 INCHES |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE |
ABDH | Single Feedthru Receptacle Quantity | 6 |
FEAT | Special Features | 1/3 BREAKDOWN VOLTAGE 300 VRMS |
SFTT | Surface Treatment | CADMIUM TERMINALS AND NICKEL TERMINALS |
CWLN | Terminal Design | NONFEEDTHRU |
CWLG | Terminal Pattern Arrangement | SINGLE ROW |
ABCS | Terminal Row Quantity | 1 |