5940-01-095-2434

TERMINAL,FEEDTHRU


5940-01-095-2434 (5940010952434, 010952434)
Part Numbers (2 listings): 1218-TP62 | 978042-1C |
Summary

FSG 59 / FSC 5940

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 May 1980

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5940-01-095-2434 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1218-TP623 - Design Control Reference2 - Production ItemHERMETIC SEAL CORPORATION  04820      
978042-1C7 - Vendor Item Drawing Reference2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5940-01-095-2434 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595940010952434A006B034672X43ANA26 May 1980
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Lugs, Terminals, and Terminal Strips

010952434

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5940-01-095-2434

A006B0

Federal Item Identification Guide (FIIG_4065)

34672

Item Naming Code (INC_4080)

26 May 1980

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5940-01-095-2434 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
N9BGN9GD3HZKEKE1 Aug 2004
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5940-01-095-2434 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4325CXD1218-TP62  04820  
4722CXD978042-1C  82577   CAGE/82577
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5940-01-095-2434 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX04 Apr 1982
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Apr 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5940-01-095-2434 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX72DZ9AHZG063330X34400ELECTRICAL-TERMINAL-TERMINAL-BLOCKS
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

G

Less Than Truckload (CLAS_RTNG_CD_2770)


125

063330

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34400

Uniform Freight Classification (UFC_CD_MODF_3040)

ELECTRICAL-TERMINAL-TERMINAL-BLOCKS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5940-01-095-2434 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5940-01-095-2434 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGTABasic Shape StyleNONTUBULAR HEX
AAGWWidth Across Flats0.375 INCHES
AAJTOverall Height0.690 INCHES
CSZGFirst End Terminal Length0.218 INCHES
CSZQSecond End Terminal Length0.222 INCHES
CSFJConductor Accommodation TypeDOUBLE TURRET FIRST END
CSFJConductor Accommodation TypeFLAT WIRE W/HOLE SECOND END
AALALargest Diameter0.090 INCHES FIRST END
AALBLargest Width0.109 INCHES SECOND END
AALDTurret Minor Diameter0.062 INCHES FIRST END
AALLWire Hole Diameter0.078 INCHES SECOND END
AALXMounting Method StyleSTUD
ABETThread Length0.125 INCHES
ATGDMounting Thread SeriesUNF
AAMPMounting Thread Diameter0.250 INCHES
AALVElectrical Insulation FeatureINSULATING SLEEVE
AAPCIdentification Code ColorWHITE
MATTMaterialIRON ALLOY 52 CONDUCTOR ACCOMMODATION
MATTMaterialGLASS INSULATION
MATTMaterialSTEEL MOUNTING FACILITY
SFTTSurface TreatmentTIN OVERALL EXCEPT INSULATION SINGLE LAYER
STDCSurface Treatment Document And ClassificationMIL-T-10727,TYPE I MIL SPEC SINGLE TREATMENT RESPONSE OVERALL EXCEPT INSULATION SINGLE LAYER
CBBLFeatures ProvidedELECTRODE HERMETIC SEAL


Back to Top
Back to Top