Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
KBP11DG-24 | 3 - Design Control Reference | 2 - Production Item | TYCO ELECTRONICS CORPORATION | 77342 | ![]() |
SMC604625-1 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 000053076 | A03300 | 32512 | X | 1 | A | N | S | 14 Jun 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
ZU01 | 1 Jul 2005 | |||||||||||||||||||||||||||||
N9BN | N9ND | 3 | L | Z | HD | GT | HD | 1 Nov 2005 | ||||||||||||||||||||||
A918 | A196 | 3 | L | Z | CD | 1 Nov 2005 | ||||||||||||||||||||||||
BGX1 | BTX1 | 3 | L | 1 Nov 2005 | ||||||||||||||||||||||||||
C911 | C007 | 3 | L | 1 Nov 2005 | ||||||||||||||||||||||||||
FXGX | FXTX | 3 | L | Z | SX | 1 Nov 2005 | ||||||||||||||||||||||||
YA01 | 1 Jan 2011 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | KBP11DG-24 | 77342 | ![]() | ||||||
C | 1 | 6 | ZZ | AC | SMC604625-1 | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Navy
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | J | U | 1 | A | EA | 0 | |
DF | SMS | J | U | 1 | N | EA | 0 | |
DN | SMS | J | U | 1 | EA | 0 | ||
DS | SMS | J | U | 1 | N | EA | 0 | |
GP | SMS | J | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA | 0.5 lbs | 0.021 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | DA | X | D1 | DO | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
A-A-1051, paperboard cushioning
As required to protect the item or elements of the package
PPP-B-566 or PPP-B-676, folding or setup box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CRNG | Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD |
APNQ | Arc Quenching Method | AIR |
APCN | Coil Quantity | 2 |
AKDX | Winding Quantity | 2 |
APNA | Winding Dc Resistance Rating | 230.0 OHMS NOMINAL ALL WINDINGS |
CSXF | Operating Voltage Rating And Type At Specified Temp | 24.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CRPQ | Nominal Operating Current Rating And Type | 104.0 MILLIAMPERES DC ALL WINDINGS |
CWJB | Energizing Element Power Rating | 4.0 WATTS |
TTQY | Terminal Type And Quantity | 1 STANDARD TUBE BASE ALL FUNCTIONS |
CRXH | Time Delay | 0.02 SECONDS NOMINAL FIXED OPERATE TIME |
APNP | Duty Type | CONTINUOUS |
ADZC | Environmental Protection | DUSTPROOF |
ABHP | Overall Length | 2.406 INCHES MAXIMUM |
ABMK | Overall Width | 1.781 INCHES MAXIMUM |
ABKW | Overall Height | 4.150 INCHES MAXIMUM |
AXHR | Mounting Facility Type And Quantity | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CBBL | Features Provided | LATCHING CONTACTS |
AKSL | Purpose For Which Designed | GENERAL |
CBME | Cubic Measure | 17.783 CUBIC INCHES |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AFRG | Contact Material | SILVER |
ADTV | Case Material | PLASTIC |
PRMT | Precious Material | SILVER |
PMLC | Precious Material And Location | CONTACTS SILVER |