Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
379-1A12VDC | 3 - Design Control Reference | 2 - Production Item | COOPER WHEELOCK INC. | 02116 | ![]() |
379-1A12VDC | 3 - Design Control Reference | 2 - Production Item | COOPER WHEELOCK INC. | 02116 | ![]() |
A16199-008 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BAE SYSTEMS NATIONAL SECURITY | 12436 | ![]() |
A16199-008 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BAE SYSTEMS NATIONAL SECURITY | 12436 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 000225614 | A03300 | 30544 | X | 1 | A | N | U | 17 May 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | TX | D | 379-1A12VDC | 02116 | ![]() | ||||
3 | 7 | 2 | 1 | TX | D | A16199-008 | 12436 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 6 | 28 Oct 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | FA | 00 | 0 | A1 | D1 | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
MIL-P-130, laminated and creped wrapping paper
No requirement
Not Applicable
Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.
PPP-B-566 or PPP-B-676, folding or setup box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CRNG | Nonpile-Up Main Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CWAB | Main Contact Maximum Voltage Rating In Volts | 150.0 DC |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 125.0 MILLIAMPERES DC RESISTIVE LOAD |
APCN | Coil Quantity | 1 |
AKDX | Winding Quantity | 1 |
APNA | Winding Dc Resistance Rating | 1.48 KILOHMS NOMINAL SINGLE WINDING |
CSXF | Operating Voltage Rating And Type At Specified Temp | 16.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD ALL FUNCTIONS |
APNP | Duty Type | CONTINUOUS |
ADZC | Environmental Protection | HERMETIC |
ABHP | Overall Length | 0.750 INCHES NOMINAL |
ADAV | Overall Diameter | 0.187 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 TERMINAL SINGLE MOUNTING FACILITY |