5945-00-027-9593

RELAY,ELECTROMAGNETIC


5945-00-027-9593 (5945000279593, 000279593)
Part Numbers (3 listings): 9420133005 | 942-0133-003 | 942-0133-005 |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-027-9593 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
94201330053 - Design Control Reference2 - Production ItemHBC SOLUTIONS, INC.  88113      
942-0133-0035 - Replaced / Discontinued2 - Production ItemHBC SOLUTIONS, INC.  88113      
942-0133-0055 - Replaced / Discontinued2 - Production ItemHBC SOLUTIONS, INC.  88113      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-027-9593 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945000279593A0330032512X1ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

000279593

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-027-9593

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-027-9593 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-027-9593 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332448D9420133005  88113  
352548D942-0133-003  88113  
352448D942-0133-005  88113  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-027-9593 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX628 Mar 1971
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

28 Mar 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-027-9593 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-027-9593 Submit RFQ
MRCDecoded RequirementClear Text Reply
CWABMain Contact Maximum Voltage Rating In Volts220.0 AC
CTDLMain Contact Load Current Rating At Maximum Rated Voltage15.0 AMPERES AC RESISTIVE LOAD
APCNCoil Quantity2
AKDXWinding Quantity1
APNAWinding Dc Resistance Rating60.0 OHMS NOMINAL SINGLE WINDING
CSXFOperating Voltage Rating And Type At Specified Temp220.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
CRPQNominal Operating Current Rating And Type3.2 AMPERES AC SINGLE WINDING
AJSSFrequency In Hertz60.0 NOMINAL
TTQYTerminal Type And Quantity4 SCREW ENERGIZING ELEMENT
TTQYTerminal Type And Quantity3 SCREW CONTACTS
APNPDuty TypeCONTINUOUS
ABHPOverall Length11.625 INCHES NOMINAL
ABKWOverall Height4.500 INCHES NOMINAL
ADAVOverall Diameter8.625 INCHES NOMINAL
AXHRMounting Facility Type And Quantity4 SLOTTED HOLE SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length10.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABTDMounting Slot Width0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY


Back to Top
Back to Top