5945-00-243-6786

RELAY,ELECTROMAGNETIC


5945-00-243-6786 (5945002436786, 002436786)
Part Number (1 listing): 7108D24
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-243-6786 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7108D243 - Design Control Reference2 - Production ItemLEACH INTERNATIONAL CORPORATION  58657      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-243-6786 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945002436786A0330032512XKANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

002436786

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-243-6786

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-243-6786 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZP011 Apr 1991
ZU011 Apr 1991
ZG011 Nov 2011
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-243-6786 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ7108D24  58657  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-243-6786 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX17 Jan 1969
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

7 Jan 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-243-6786 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-243-6786 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeINTERMITTENT
APCNCoil Quantity1
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternCIRUCLAR SINGLE MOUNTING FACILITY
CRPQNominal Operating Current Rating And Type1.33 AMPERES DC SINGLE WINDING
CRNGNonpile-Up Main Contact Arrangement4 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CSXFOperating Voltage Rating And Type At Specified Temp12.0 VOLTS AC 85 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage100.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts29.0 DC
ABKWOverall Height3.594 INCHES NOMINAL
ABHPOverall Length6.500 INCHES NOMINAL
ABMKOverall Width2.688 INCHES NOMINAL
FEATSpecial FeaturesINCL MECHANICAL INTERLOCK INVERTED TERMINALS
AEBVUnthreaded Mounting Hole Diameter0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNAWinding Dc Resistance Rating18.0 OHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity1
TTQYTerminal Type And Quantity12 PIN ALL FUNCTIONS


Back to Top
Back to Top