Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
827115J | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 56232 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 002580309 | A03300 | 32512 | X | M | 3 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 6 May 1969 | 5945002556438 | 1 Apr 1965 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNP | Duty Type | CONTINUOUS |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 0.933 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.943 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
APCN | Coil Quantity | 1 |
AGAV | End Item Identification | TYPE AN/SPQ-5 |
ADZC | Environmental Protection | HERMETIC |
AJSS | Frequency In Hertz | 60.0 NOMINAL |
AXHR | Mounting Facility Type And Quantity | 3 THREADED STUD SINGLE MOUNTING FACILITY |
CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
CRPQ | Nominal Operating Current Rating And Type | 242.0 MILLIAMPERES AC SINGLE WINDING |
CQJX | Nominal Thread Size | 0.138 INCHES SINGLE MOUNTING FACILITY |
CSXF | Operating Voltage Rating And Type At Specified Temp | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 3.0 AMPERES AC RESISTIVE LOAD AND 3.0 AMPERES DC RESISTIVE LOAD |
CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC AND 27.5 DC |
FEAT | Special Features | 2ND C TO C DISTANCE BETWEEN MTG STUDS 1.187 IN. PLUS 0.005 |
ABKW | Overall Height | 2.060 INCHES MAXIMUM |
ABHP | Overall Length | 1.620 INCHES MAXIMUM |
ABMK | Overall Width | 1.430 INCHES MAXIMUM |
APNA | Winding Dc Resistance Rating | 427.5 OHMS MINIMUM SINGLE WINDING AND 522.5 OHMS MAXIMUM SINGLE WINDING |
AKDX | Winding Quantity | 1 |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |