Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8D29G5DDD22 | 3 - Design Control Reference | 9 - No Longer Used | ITT TELECOM PRODUCTS CORP | 21340 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 002683559 | A03300 | 32512 | X | 1 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G900 | 0 | 0 | L | 1 Apr 1991 |
Not Established
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 5 | TX | 8D29G5DDD22 | 21340 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 3 Mar 1971 | 5945000600687 | 13 Mar 1971 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AYSC | Pile-Up Main Contact Form Arrangement | 1C AND 1C AND 1C |
CWAB | Main Contact Maximum Voltage Rating In Volts | 50.0 DC |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 500.0 MILLIAMPERES DC RESISTIVE LOAD |
APCN | Coil Quantity | 1 |
AKDX | Winding Quantity | 1 |
APNA | Winding Dc Resistance Rating | 200.0 OHMS NOMINAL SINGLE WINDING |
CSXF | Operating Voltage Rating And Type At Specified Temp | 50.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CRPQ | Nominal Operating Current Rating And Type | 31.0 MILLIAMPERES DC SINGLE WINDING |
TTQY | Terminal Type And Quantity | 9 WIRE LEAD ENERGIZING ELEMENT |
TTQY | Terminal Type And Quantity | 2 WIRE LEAD CONTACTS |
APNP | Duty Type | CONTINUOUS |
ABHP | Overall Length | 4.870 INCHES NOMINAL |
ABMK | Overall Width | 1.000 INCHES NOMINAL |
ABKW | Overall Height | 1.680 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |