Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
16-04-0029B-009 | 3 - Design Control Reference | 9 - No Longer Used | FEDDERS NORTH AMERICA INC | 05481 | ![]() |
16-04-00290-009 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEDDERS NORTH AMERICA INC | 05481 | ![]() |
3ARR3CV3P4 | 5 - Replaced / Discontinued | 9 - No Longer Used | GENERAL ELECTRIC CO | 03513 | ![]() |
16-04-00290-009 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEDDERS CORP | 91402 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 004813392 | A03300 | 32512 | X | 1 | A | N | U | 12 Jun 1974 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 3 | C | Z | HD | HD | 1 Jul 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | A | TX | 16-04-0029B-009 | 05481 | ![]() | ||||||
5 | 9 | 5 | TX | B | 16-04-00290-009 | 91402 | ![]() | |||||
5 | 9 | E | TX | B | 3ARR3CV3P4 | 03513 | ![]() | |||||
4 | 5 | 9 | A | TX | B | 16-04-00290-009 | 05481 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | TX | 0 | 1 Dec 1974 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | ZZ | Q | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNP | Duty Type | CONTINUOUS |
APNQ | Arc Quenching Method | AIR |
ADTV | Case Material | METAL |
CSQJ | Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle | 0.600 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.305 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | Coil Quantity | 1 |
ADZC | Environmental Protection | HERMETIC |
AFJN | Fragility Factor | MODERATELY RUGGED |
AJSS | Frequency In Hertz | 60.0 NOMINAL |
CBME | Cubic Measure | 0.375 CUBIC INCHES |
AXHR | Mounting Facility Type And Quantity | 3 THREADED STUD SINGLE MOUNTING FACILITY |
CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.138 INCHES SINGLE MOUNTING FACILITY |
CRNG | Nonpile-Up Main Contact Arrangement | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | Operating Voltage Rating And Type At Specified Temp | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD AND 500.0 MILLIAMPERES DC RESISTIVE LOAD |
CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC AND 28.0 DC |
AKSL | Purpose For Which Designed | GENERAL |
ABKW | Overall Height | 0.750 INCHES MAXIMUM |
ABHP | Overall Length | 1.000 INCHES MAXIMUM |
ABMK | Overall Width | 0.500 INCHES MAXIMUM |
AKDX | Winding Quantity | 1 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 11 WIRE HOOK ALL FUNCTIONS |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AAJF | Thread Direction | RIGHT-HAND SINGLE MOUNTING FACILITY |
CMLP | Thread Quantity Per Inch | 32 SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |
CRXH | Time Delay | 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |