5945-00-498-4331

RELAY,ELECTROMAGNETIC


5945-00-498-4331 (5945004984331, 004984331)
Part Numbers (2 listings): 616518-1 | 616518-1V1A |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 7

HMIC: N

Date Created: 17 Oct 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-498-4331 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
616518-13 - Design Control Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  56232    CAGE 56232  
616518-1V1A5 - Replaced / Discontinued2 - Production ItemLOCKHEED MARTIN CORPORATION  56232    CAGE 56232  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-498-4331 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945004984331A0330032512XLANA017 Oct 1969
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

004984331

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-498-4331

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

17 Oct 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

L

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference - Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-498-4331 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-498-4331 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3311HDD616518-1  56232   CAGE/56232
1526HDB616518-1V1A  56232   CAGE/56232
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-498-4331 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX021 Dec 1969
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Dec 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-498-4331 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HDP658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

HD

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-00-498-4331 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNN35DU1EA0
DNN35VU1MEA0
Code Definitions

N35

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

M

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: Medium Demand Velocity Items (Consumables)

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-498-4331 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCNCoil Quantity1
ADZCEnvironmental ProtectionHERMETIC
AXHRMounting Facility Type And Quantity2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage1.0 AMPERES AC INDUCTIVE LOAD AND 500.0 MILLIAMPERES DC INDUCTIVE LOAD
CTDLMain Contact Load Current Rating At Maximum Rated Voltage1.5 AMPERES AC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts115.0 AC AND 28.0 DC
ZZZYReference Number Differentiating CharacteristicsAS DIFFERENTIATED BY SPECIAL TEST FEATURES
ABKWOverall Height1.312 INCHES MAXIMUM
ABHPOverall Length1.984 INCHES NOMINAL
ABMKOverall Width1.875 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.145 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNAWinding Dc Resistance Rating200.0 OHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity1
SPCLSpecial Test FeaturesNAVORD OD41152
TTQYTerminal Type And Quantity20 WIRE HOOK ALL FUNCTIONS


Back to Top