5945-00-518-9122

RELAY,ELECTROMAGNETIC


5945-00-518-9122 (5945005189122, 005189122)
Part Numbers (16 listings): W389ACXUDIN-4 | 389CD2P11 | R2001-5071PCSYMB0LK4 | 574-6504-810756REVBPC15 | 574-6505-810755REVAPC24 | 574-6504-810757REVAPC16 | 6504-807102REVAPC42 | 426-6505-802803ITEM94 | 484-6505-802810PC6 | 490-6505-802603REVAPC22 | 320-6505-798940REVCPC48 | 320-6505-798938REVCPC24 | 282-6505-803096PC19 | 313-6504-818874PC4 | 317-6504-807445REVBPC13 | 2200-771744REVAPC24 |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 0.4 lbs

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-518-9122 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
W389ACXUDIN-43 - Design Control Reference2 - Production ItemSE RELAYS LLC MAGNECRAFT  94696    CAGE 94696  
389CD2P115 - Replaced / Discontinued9 - No Longer UsedWARD LEONARD ELECTRIC COMPANY INC.  63743    CAGE 63743  
R2001-5071PCSYMB0LK45 - Replaced / Discontinued9 - No Longer UsedTELEDYNE TECHNOLOGIES INC  98571    CAGE 98571  
574-6504-810756REVBPC155 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
574-6505-810755REVAPC245 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
574-6504-810757REVAPC165 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
6504-807102REVAPC425 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
426-6505-802803ITEM945 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
484-6505-802810PC65 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
490-6505-802603REVAPC225 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
320-6505-798940REVCPC485 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
320-6505-798938REVCPC245 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
282-6505-803096PC195 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
313-6504-818874PC45 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
317-6504-807445REVBPC135 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2200-771744REVAPC245 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-518-9122 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945005189122A0330032512X1ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

005189122

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-518-9122

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-518-9122 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Jul 1997
ZW011 Nov 1998
YB011 Jun 2003
C911C0073Z1 Nov 2005
N9BNN9ND3ZZHDHD1 Nov 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-518-9122 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETXW389ACXUDIN-4  94696   CAGE/94696
3595TXBR2001-5071PCSYMB0LK4  98571   CAGE/98571
595TXB389CD2P11  63743   CAGE/63743
3595TXB2200-771744REVAPC24  80064   CAGE/80064
3595TXB282-6505-803096PC19  80064   CAGE/80064
3595TXB313-6504-818874PC4  80064   CAGE/80064
3595TXB317-6504-807445REVBPC13  80064   CAGE/80064
3595TXB320-6505-798938REVCPC24  80064   CAGE/80064
3595TXB320-6505-798940REVCPC48  80064   CAGE/80064
3595TXB426-6505-802803ITEM94  80064   CAGE/80064
3595TXB484-6505-802810PC6  80064   CAGE/80064
3595TXB490-6505-802603REVAPC22  80064   CAGE/80064
3595TXB574-6504-810756REVBPC15  80064   CAGE/80064
3595TXB574-6504-810757REVAPC16  80064   CAGE/80064
3595TXB574-6505-810755REVAPC24  80064   CAGE/80064
3595TXB6504-807102REVAPC42  80064   CAGE/80064
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-518-9122 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
5GX01 Nov 2007
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

GX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Nov 2007

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-518-9122 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P72DZ9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-00-518-9122 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
GPSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5945-00-518-9122 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.4 lbs
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD3DOZZQQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.4 lbs

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-518-9122 Submit RFQ
MRCDecoded RequirementClear Text Reply
CRNGNonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CWABMain Contact Maximum Voltage Rating In Volts125.0 AC
CTDLMain Contact Load Current Rating At Maximum Rated Voltage15.0 AMPERES AC RESISTIVE LOAD
APCNCoil Quantity1
AKDXWinding Quantity1
APNAWinding Dc Resistance Rating335.0 OHMS NOMINAL SINGLE WINDING
CSXFOperating Voltage Rating And Type At Specified Temp115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
CRPQNominal Operating Current Rating And Type60.0 MILLIAMPERES AC SINGLE WINDING
AJSSFrequency In Hertz60.0 NOMINAL
TTQYTerminal Type And Quantity8 PIN ALL FUNCTIONS
APNPDuty TypeCONTINUOUS
ABHPOverall Length2.750 INCHES NOMINAL
ABMKOverall Width2.500 INCHES NOMINAL
ABKWOverall Height1.750 INCHES NOMINAL
AXHRMounting Facility Type And Quantity2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AEBVUnthreaded Mounting Hole Diameter0.169 INCHES NOMINAL SINGLE MOUNTING FACILITY


Back to Top
Back to Top