Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
271-1378P3 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON CO | 99687 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 005838852 | A03300 | 32512 | X | M | 3 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 6 May 1969 | 5945008109084 | 1 Apr 1965 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNP | Duty Type | CONTINUOUS |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | Coil Quantity | 1 |
ADZC | Environmental Protection | HERMETIC |
AJSS | Frequency In Hertz | 60.0 NOMINAL OR 400.0 NOMINAL |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
CRPQ | Nominal Operating Current Rating And Type | 30.0 MILLIAMPERES AC SINGLE WINDING |
CSXF | Operating Voltage Rating And Type At Specified Temp | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 AMPERES AC INDUCTIVE LOAD AND 2.0 AMPERES DC INDUCTIVE LOAD |
CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC AND 26.5 DC |
ABKW | Overall Height | 1.950 INCHES NOMINAL |
ABHP | Overall Length | 1.840 INCHES NOMINAL |
ABMK | Overall Width | 1.310 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.144 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA | Winding Dc Resistance Rating | 3.700 KILOHMS NOMINAL SINGLE WINDING |
AKDX | Winding Quantity | 1 |