Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7012-0HBC | 3 - Design Control Reference | 2 - Production Item | TYCO ELECTRONICS/AGASTAT RELAYS | 89020 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 006266440 | A03300 | 32512 | X | 1 | A | N | U | 5 Mar 1975 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | 7012-0HBC | 89020 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Apr 1975 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF |
France
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNP | Duty Type | CONTINUOUS |
APNQ | Arc Quenching Method | AIR |
ADTV | Case Material | PLASTIC |
AEBW | Center To Center Distance Between Mounting Facilities Parallel To Height | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | Center To Center Distance Between Mounting Facilities Parallel To Height | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
APCN | Coil Quantity | 1 |
CWJB | Energizing Element Power Rating | 8.0 WATTS |
ADZC | Environmental Protection | DUSTPROOF |
AFJN | Fragility Factor | MODERATELY RUGGED |
CBME | Cubic Measure | 45.392 CUBIC INCHES |
CQYJ | Mounting Facility Pattern | RECTANGULAR FIRST MOUNTING FACILITY |
CQYJ | Mounting Facility Pattern | RECTANGULAR SECOND MOUNTING FACILITY |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE SECOND MOUNTING FACILITY |
AXHR | Mounting Facility Type And Quantity | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.164 INCHES SECOND MOUNTING FACILITY |
CRNG | Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | Operating Voltage Rating And Type At Specified Temp | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWAB | Main Contact Maximum Voltage Rating In Volts | 240.0 AC AND 30.0 DC |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
AKSL | Purpose For Which Designed | GENERAL |
ABKW | Overall Height | 4.520 INCHES MAXIMUM |
ABHP | Overall Length | 3.250 INCHES MAXIMUM |
ABMK | Overall Width | 3.090 INCHES MAXIMUM |
AEBV | Unthreaded Mounting Hole Diameter | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AKDX | Winding Quantity | 1 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 8 SCREW ALL FUNCTIONS |
AAJD | Thread Class | 2B SECOND MOUNTING FACILITY |
AAJF | Thread Direction | RIGHT-HAND SECOND MOUNTING FACILITY |
CMLP | Thread Quantity Per Inch | 32 SECOND MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SECOND MOUNTING FACILITY |
CRXH | Time Delay | 3.00 MINUTES MINIMUM ADJUSTABLE OPERATE TIME AND 30.00 MINUTES MAXIMUM ADJUSTABLE OPERATE TIME |