5945-00-813-8700

RELAY,ELECTROMAGNETIC


5945-00-813-8700 (5945008138700, 008138700)
Part Numbers (3 listings): 974-0767-00 | 974-0767-000 | 9225 |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1962

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-813-8700 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
974-0767-003 - Design Control Reference2 - Production ItemALCATEL USA INC.  95104    CAGE 95104  
974-0767-0005 - Replaced / Discontinued2 - Production ItemALCATEL USA INC.  95104    CAGE 95104  
92255 - Replaced / Discontinued2 - Production ItemLEACH INTERNATIONAL CORPORATION  58657      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-813-8700 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945008138700A0330032512XKANU1 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

008138700

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-813-8700

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-813-8700 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-813-8700 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3525TXD974-0767-000  95104   CAGE/95104
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-813-8700 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59601 Jan 1996
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

96

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Jan 1996

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-813-8700 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-00-813-8700 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5945-00-813-8700 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000BGXD1DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

BG

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


A-A-1898, Grade II, water resistant cellulosic cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-813-8700 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCNCoil Quantity1
ADZCEnvironmental ProtectionHERMETIC
CBBLFeatures ProvidedPOLARIZED AND LATCHING CONTACTS
CQYJMounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
AXHRMounting Facility Type And Quantity4 THREADED STUD SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts115.0 AC
ABKWOverall Height1.530 INCHES NOMINAL
ABHPOverall Length1.810 INCHES NOMINAL
ABMKOverall Width1.530 INCHES NOMINAL
APNAWinding Dc Resistance Rating200.0 OHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity2
TTQYTerminal Type And Quantity14 PIN ALL FUNCTIONS
AAJDThread Class2A SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNC SINGLE MOUNTING FACILITY


Back to Top
Back to Top