| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 31601 | 3 - Design Control Reference | 9 - No Longer Used | COOPER INDUSTRIES INC | 04009 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 008518890 | A03300 | 32512 | X | 1 | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZF01 | 1 Feb 1997 | |||||||||||||||||||||||||||||
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 28 Mar 1971 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 723 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CRNG | Nonpile-Up Main Contact Arrangement | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CSKP | Nonpile-Up Auxiliary Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 550.0 AC |
| CSQC | Auxiliary Contact Maximum Voltage Rating In Volts | 110.0 AC |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 30.0 AMPERES AC RESISTIVE LOAD |
| APCN | Coil Quantity | 1 |
| AKDX | Winding Quantity | 1 |
| APNA | Winding Dc Resistance Rating | 48.0 OHMS NOMINAL SINGLE WINDING |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 110.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| CRPQ | Nominal Operating Current Rating And Type | 100.0 MILLIAMPERES AC SINGLE WINDING |
| AJSS | Frequency In Hertz | 60.0 NOMINAL |
| TTQY | Terminal Type And Quantity | 10 PIN ALL FUNCTIONS |
| APNP | Duty Type | CONTINUOUS |
| ABHP | Overall Length | 3.870 INCHES NOMINAL |
| ABMK | Overall Width | 3.810 INCHES NOMINAL |
| ABKW | Overall Height | 3.210 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
| CSQJ | Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AEBV | Unthreaded Mounting Hole Diameter | 0.172 INCHES NOMINAL SINGLE MOUNTING FACILITY |