5945-00-928-7910

RELAY,ELECTROMAGNETIC


5945-00-928-7910 (5945009287910, 009287910)
Part Number (1 listing): B-16239
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 Aug 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-928-7910 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
B-162393 - Design Control Reference9 - No Longer UsedAIRPAX CORP LLC  82415      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-928-7910 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945009287910A0330032512X1ANS26 Aug 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

009287910

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-928-7910

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

26 Aug 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-928-7910 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND5DZGHHD1 Nov 2005
Code Definitions

5

Acquisition Method Code (AMC_2871)


Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.

D

Acquisition Method Suffix Code (AMSC_2876)


The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-928-7910 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4391TXDB-16239  82415  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-928-7910 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX03 Sep 1970
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Sep 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-928-7910 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TXP72DZ9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

P

Less Than Carload (LCL_CD_2760)


77.5

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-00-928-7910 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1EA0
DSSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-928-7910 Submit RFQ
MRCDecoded RequirementClear Text Reply
CRNGNonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CWABMain Contact Maximum Voltage Rating In Volts120.0 AC
CTDLMain Contact Load Current Rating At Maximum Rated Voltage5.0 AMPERES AC RESISTIVE LOAD
APCNCoil Quantity1
AKDXWinding Quantity1
APNAWinding Dc Resistance Rating27.0 OHMS NOMINAL SINGLE WINDING
CSXFOperating Voltage Rating And Type At Specified Temp6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TTQYTerminal Type And Quantity5 WIRE HOOK ALL FUNCTIONS
APNPDuty TypeCONTINUOUS
ADZCEnvironmental ProtectionDUSTPROOF
ABHPOverall Length1.344 INCHES MAXIMUM
ABMKOverall Width0.953 INCHES MAXIMUM
ABKWOverall Height1.950 INCHES NOMINAL
AXHRMounting Facility Type And Quantity3 THREADED STUD SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternTRIANGLE SINGLE MOUNTING FACILITY
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY
CSQJCenter To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNC SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.112 INCHES SINGLE MOUNTING FACILITY
AAJDThread Class2A SINGLE MOUNTING FACILITY
CMLPThread Quantity Per Inch40 SINGLE MOUNTING FACILITY
AFRGContact MaterialSILVER
PRMTPrecious MaterialSILVER
PMLCPrecious Material And LocationCONTACTS SILVER


Back to Top
Back to Top