5945-00-945-7535

RELAY,ELECTROMAGNETIC


5945-00-945-7535 (5945009457535, 009457535)
Part Numbers (2 listings): KHS17D11 | KHS17D11-90VDC |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 20 Nov 1971

Unit Weight: None

Unit Size:

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-00-945-7535 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
KHS17D113 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  77342    CAGE 77342  
KHS17D11-90VDC5 - Replaced / Discontinued9 - No Longer UsedTYCO ELECTRONICS CORPORATION  77342    CAGE 77342  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5945-00-945-7535 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945009457535A0330032512X43ANAC020 Nov 1971
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

009457535

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-00-945-7535

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

20 Nov 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

C

Precious Metals Indicator Code (PMIC_0802)


Item contains combination of two or more precious metals (silver, gold, platinum).

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5945-00-945-7535 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
R47A001 Aug 2001
YD011 Sep 2016
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established


FLIS - SEG C - REFERENCE NUMBER | NSN 5945-00-945-7535 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZKHS17D11  77342   CAGE/77342
359ETXBKHS17D11-90VDC  77342   CAGE/77342
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-00-945-7535 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-00-945-7535 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-00-945-7535 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
RAG13GU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

G13

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Department of Commerce, National Oceanic and Atmospheric Administration, National Weather Service - Engineering Division, 1325 East-West Highway, W/0S0322, SSMC2, Silver Springs, MD 20910

G

Acquisition Advice Code (AAC_2507)


GENERAL SERVICES ADMINISTRATION (GSA)/CIVIL AGENCY INTEGRATED MATERIEL MANAGED, STOCKED AND ISSUED Identifies GSA/Civil Agency-managed items available from GSA/Civil Agency supply distribution facilities. Requisitions and fund citations will be submitted in accordance with GSA/Civil Agency/Service requisitioning procedures.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

RA

Service / Agency Code (MOE_CD_2833)


National Weather Service


FLIS - SEG W - PACKAGING DATA | NSN 5945-00-945-7535 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FA000A1D1QQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

A1

Unit Container Code (UNIT_CTNR_CD_5166)


Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-00-945-7535 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
AGAVEnd Item IdentificationAUTOMATED RADIO THEODOLITE SYSTEM (ART-1,1R,2,2R)
ADTVCase MaterialMETAL
APCNCoil Quantity1
AFRGContact MaterialSILVER
AFRHContact Surface TreatmentGOLD FLASH
CWJBEnergizing Element Power Rating900.0 MILLIWATTS
ADZCEnvironmental ProtectionHERMETIC
AFJNFragility FactorMODERATELY RUGGED
AXHRMounting Facility Type And Quantity1 THREADED STUD SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.099 INCHES SINGLE MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp90.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage3.0 AMPERES AC RESISTIVE LOAD AND 3.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts120.0 AC AND 30.0 DC
PMLCPrecious Material And LocationCONTACTS SILVER AND CONTACT SURFACES GOLD
PRMTPrecious MaterialSILVER AND GOLD
ABKWOverall Height1.593 INCHES NOMINAL
ABHPOverall Length1.156 INCHES MAXIMUM
ABMKOverall Width0.910 INCHES MAXIMUM
APNAWinding Dc Resistance Rating9.0 KILOHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity14 TAB, SOLDER LUG ALL FUNCTIONS
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND SINGLE MOUNTING FACILITY
CMLPThread Quantity Per Inch48 SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNC SINGLE MOUNTING FACILITY
CRXHTime Delay0.006 SECONDS NOMINAL FIXED RELEASE TIME
CRXHTime Delay0.013 SECONDS NOMINAL FIXED OPERATE TIME


Back to Top
Back to Top