| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| PR11AY | 3 - Design Control Reference | 1 - Incomplete Part Number | TYCO ELECTRONICS CORPORATION | 77342 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 009738369 | A03300 | 32512 | X | N | 3 | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 3 | TX | 0 | 1 | TX | 0 | 21 Feb 1970 | 5945009002863 | 21 Oct 1970 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| APNP | Duty Type | CONTINUOUS |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APCN | Coil Quantity | 1 |
| AJSS | Frequency In Hertz | 60.0 NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| CQYJ | Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 230.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 13.0 AMPERES AC RESISTIVE LOAD |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 230.0 AC |
| ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY CURRENT TYPE,WINDING QUANTITY,INDUCTIVE WINDING QUANTITY,WINDING DC RESISTANCE RATING,AC FREQUENCY RATING,MAIN CONTACT VOLTAGE RATING |
| ABKW | Overall Height | 2.500 INCHES NOMINAL |
| ABHP | Overall Length | 3.375 INCHES NOMINAL |
| ABMK | Overall Width | 2.500 INCHES NOMINAL |
| AEBV | Unthreaded Mounting Hole Diameter | 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APNA | Winding Dc Resistance Rating | 1.2 KILOHMS NOMINAL SINGLE WINDING |
| AKDX | Winding Quantity | 1 |