5945-01-008-2149

RELAY,ELECTROMAGNETIC


5945-01-008-2149 (5945010082149, 010082149)
Part Number (1 listing): 7012EE
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 17 Aug 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-008-2149 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7012EE3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS/AGASTAT RELAYS  89020    CAGE 89020  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-008-2149 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945010082149A0330032512X1ANU17 Aug 1975
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

010082149

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-008-2149

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

17 Aug 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-008-2149 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZH011 Mar 1999
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-008-2149 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX7012EE  89020   CAGE/89020
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-01-008-2149 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Aug 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Aug 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-008-2149 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
83P658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

83

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Energy, New York, NY 10014

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-008-2149 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
APNQArc Quenching MethodAIR
ADTVCase MaterialPLASTIC
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.500 INCHES NOMINAL SECOND MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.750 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.880 INCHES NOMINAL FIRST MOUNTING FACILITY
APCNCoil Quantity1
CWJBEnergizing Element Power Rating8.0 WATTS
ADZCEnvironmental ProtectionDUSTPROOF
AFJNFragility FactorMODERATELY RUGGED
AJSSFrequency In Hertz60.0 NOMINAL
CBMECubic Measure45.392 CUBIC INCHES
CQYJMounting Facility PatternRECTANGULAR FIRST MOUNTING FACILITY
CQYJMounting Facility PatternRECTANGULAR SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity4 THREADED HOLE SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity6 UNTHREADED HOLE FIRST MOUNTING FACILITY
CQJXNominal Thread Size0.164 INCHES SECOND MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp24.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
CWABMain Contact Maximum Voltage Rating In Volts240.0 AC AND 30.0 DC
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD
AKSLPurpose For Which DesignedGENERAL
ABKWOverall Height4.520 INCHES MAXIMUM
ABHPOverall Length3.250 INCHES MAXIMUM
ABMKOverall Width3.090 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.199 INCHES NOMINAL FIRST MOUNTING FACILITY
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity8 SCREW ALL FUNCTIONS
AAJDThread Class2B SECOND MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND SECOND MOUNTING FACILITY
CMLPThread Quantity Per Inch32 SECOND MOUNTING FACILITY
THSDThread Series DesignatorUNC SECOND MOUNTING FACILITY
CRXHTime Delay20.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 200.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME


Back to Top