5945-01-010-1476

RELAY,ELECTROMAGNETIC


5945-01-010-1476 (5945010101476, 010101476)
Part Number (1 listing): KHS17D21-24
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 22 Sep 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-010-1476 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
KHS17D21-243 - Design Control Reference9 - No Longer UsedPOTTER AND BRUMFIELD DIV AMF CANADA  12300      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-010-1476 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945010101476A0330032512X49ANC22 Sep 1975
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

010101476

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-010-1476

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

22 Sep 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

C

Precious Metals Indicator Code (PMIC_0802)


Item contains combination of two or more precious metals (silver, gold, platinum).


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-010-1476 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG
ZG011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-010-1476 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
139ETXDKHS17D21-24  12300  
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-010-1476 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-010-1476 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
ADTVCase MaterialMETAL
APCNCoil Quantity1
AFRGContact MaterialSILVER
AFRHContact Surface TreatmentGOLD FLASH
CWJBEnergizing Element Power Rating900.0 MILLIWATTS
ADZCEnvironmental ProtectionHERMETIC
AFJNFragility FactorMODERATELY RUGGED
AXHRMounting Facility Type And Quantity1 THREADED STUD FIRST MOUNTING FACILITY
AXHRMounting Facility Type And Quantity1 THREADED STUD SECOND MOUNTING FACILITY
CQJXNominal Thread Size0.099 INCHES FIRST MOUNTING FACILITY
CQJXNominal Thread Size0.138 INCHES SECOND MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage3.0 AMPERES AC RESISTIVE LOAD AND 3.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts120.0 AC AND 30.0 DC
PMLCPrecious Material And LocationCONTACTS SILVER AND CONTACT SURFACES GOLD
PRMTPrecious MaterialSILVER AND GOLD
ABKWOverall Height0.910 INCHES MAXIMUM
ABHPOverall Length1.616 INCHES NOMINAL
ABMKOverall Width1.593 INCHES NOMINAL
APNAWinding Dc Resistance Rating650.0 OHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity14 TAB, SOLDER LUG ALL FUNCTIONS
AAJDThread Class2A FIRST MOUNTING FACILITY
AAJDThread Class2A SECOND MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND FIRST MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND SECOND MOUNTING FACILITY
AASAThread Length0.312 INCHES NOMINAL FIRST MOUNTING FACILITY
AASAThread Length0.375 INCHES NOMINAL SECOND MOUNTING FACILITY
CMLPThread Quantity Per Inch32 SECOND MOUNTING FACILITY
CMLPThread Quantity Per Inch48 FIRST MOUNTING FACILITY
THSDThread Series DesignatorUNC FIRST MOUNTING FACILITY
THSDThread Series DesignatorUNC SECOND MOUNTING FACILITY
CRXHTime Delay0.006 SECONDS NOMINAL FIXED RELEASE TIME
CRXHTime Delay0.013 SECONDS NOMINAL FIXED OPERATE TIME


Back to Top