Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
KHS17D21-24 | 3 - Design Control Reference | 9 - No Longer Used | POTTER AND BRUMFIELD DIV AMF CANADA | 12300 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5945 | 010101476 | A03300 | 32512 | X | 4 | 9 | A | N | C | 22 Sep 1975 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains combination of two or more precious metals (silver, gold, platinum).
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG | ||||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | E | TX | D | KHS17D21-24 | 12300 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNP | Duty Type | CONTINUOUS |
ADTV | Case Material | METAL |
APCN | Coil Quantity | 1 |
AFRG | Contact Material | SILVER |
AFRH | Contact Surface Treatment | GOLD FLASH |
CWJB | Energizing Element Power Rating | 900.0 MILLIWATTS |
ADZC | Environmental Protection | HERMETIC |
AFJN | Fragility Factor | MODERATELY RUGGED |
AXHR | Mounting Facility Type And Quantity | 1 THREADED STUD FIRST MOUNTING FACILITY |
AXHR | Mounting Facility Type And Quantity | 1 THREADED STUD SECOND MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.099 INCHES FIRST MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.138 INCHES SECOND MOUNTING FACILITY |
CRNG | Nonpile-Up Main Contact Arrangement | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | Operating Voltage Rating And Type At Specified Temp | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 3.0 AMPERES AC RESISTIVE LOAD AND 3.0 AMPERES DC RESISTIVE LOAD |
CWAB | Main Contact Maximum Voltage Rating In Volts | 120.0 AC AND 30.0 DC |
PMLC | Precious Material And Location | CONTACTS SILVER AND CONTACT SURFACES GOLD |
PRMT | Precious Material | SILVER AND GOLD |
ABKW | Overall Height | 0.910 INCHES MAXIMUM |
ABHP | Overall Length | 1.616 INCHES NOMINAL |
ABMK | Overall Width | 1.593 INCHES NOMINAL |
APNA | Winding Dc Resistance Rating | 650.0 OHMS NOMINAL SINGLE WINDING |
AKDX | Winding Quantity | 1 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 14 TAB, SOLDER LUG ALL FUNCTIONS |
AAJD | Thread Class | 2A FIRST MOUNTING FACILITY |
AAJD | Thread Class | 2A SECOND MOUNTING FACILITY |
AAJF | Thread Direction | RIGHT-HAND FIRST MOUNTING FACILITY |
AAJF | Thread Direction | RIGHT-HAND SECOND MOUNTING FACILITY |
AASA | Thread Length | 0.312 INCHES NOMINAL FIRST MOUNTING FACILITY |
AASA | Thread Length | 0.375 INCHES NOMINAL SECOND MOUNTING FACILITY |
CMLP | Thread Quantity Per Inch | 32 SECOND MOUNTING FACILITY |
CMLP | Thread Quantity Per Inch | 48 FIRST MOUNTING FACILITY |
THSD | Thread Series Designator | UNC FIRST MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SECOND MOUNTING FACILITY |
CRXH | Time Delay | 0.006 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | Time Delay | 0.013 SECONDS NOMINAL FIXED OPERATE TIME |