| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| MF23A120 | 3 - Design Control Reference | 9 - No Longer Used | TYCO ELECTRONICS CORPORATION | 77342 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 010325516 | A03300 | 32512 | X | 1 | A | N | U | 15 Dec 1976 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZZ | ||||||||||||||||||||||||||||||
| N9BN | 3 | L | Z | HD | HD | 1 Nov 2005 | ||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 9 | 3 | TX | D | MF23A120 | 77342 | | ||||
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | P | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AYSC | Pile-Up Main Contact Form Arrangement | 6C |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 120.0 AC |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 5.0 AMPERES AC RESISTIVE LOAD |
| APCN | Coil Quantity | 1 |
| AKDX | Winding Quantity | 1 |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| AJSS | Frequency In Hertz | 60.0 NOMINAL |
| TTQY | Terminal Type And Quantity | 20 PIN ALL FUNCTIONS |
| CRXH | Time Delay | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | Time Delay | 0.02 SECONDS MAXIMUM FIXED RELEASE TIME |
| APNP | Duty Type | CONTINUOUS |
| ABHP | Overall Length | 1.984 INCHES NOMINAL |
| ABMK | Overall Width | 1.062 INCHES NOMINAL |
| ABKW | Overall Height | 1.593 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
| CQYJ | Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |
| CQJX | Nominal Thread Size | 0.138 INCHES SINGLE MOUNTING FACILITY |
| AAJD | Thread Class | 2B SINGLE MOUNTING FACILITY |
| CMLP | Thread Quantity Per Inch | 32 SINGLE MOUNTING FACILITY |