5945-01-038-6876

RELAY,ELECTROMAGNETIC


5945-01-038-6876 (5945010386876, 010386876)
Part Numbers (2 listings): KR5AK-12V | KR5AK12V |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 10 Apr 1977

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-038-6876 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
KR5AK-12V3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  77342    CAGE 77342  
KR5AK12VC - Advisory Reference1 - Incomplete Part NumberPOTTER AND BRUMFIELD DIV AMF CANADA  12300      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-038-6876 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945010386876A0330032512X49ANU10 Apr 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

010386876

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-038-6876

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

10 Apr 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-038-6876 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YS011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-038-6876 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4323TXDKR5AK-12V  77342   CAGE/77342
4C13TXDKR5AK12V  12300  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-01-038-6876 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597610 Apr 1977
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

10 Apr 1977

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-038-6876 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5945-01-038-6876 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP511AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD1DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-038-6876 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
APCNCoil Quantity1
ADZCEnvironmental ProtectionHERMETIC
AXHRMounting Facility Type And Quantity1 THREADED STUD SINGLE MOUNTING FACILITY
CRPQNominal Operating Current Rating And Type168.0 MILLIAMPERES AC SINGLE WINDING
CQJXNominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CSXFOperating Voltage Rating And Type At Specified Temp12.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts120.0 AC AND 28.0 DC
ABKWOverall Height1.687 INCHES MAXIMUM
ABHPOverall Length1.937 INCHES MAXIMUM
ABMKOverall Width1.312 INCHES MAXIMUM
APNAWinding Dc Resistance Rating21.0 OHMS NOMINAL SINGLE WINDING
AKDXWinding Quantity1
TTQYTerminal Type And Quantity4 PIN ALL FUNCTIONS
AAJDThread Class2A SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNC SINGLE MOUNTING FACILITY
CRXHTime Delay0.01 SECONDS NOMINAL FIXED RELEASE TIME
CRXHTime Delay0.015 SECONDS NOMINAL FIXED OPERATE TIME


Back to Top