| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| E210-163B | 3 - Design Control Reference | 2 - Production Item | DRI RELAYS INC. | 99699 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 010698947 | A03300 | 32512 | X | 1 | A | N | U | 28 Dec 1978 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZN | ||||||||||||||||||||||||||||||
| ZZ | ||||||||||||||||||||||||||||||
| ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| VD01 | 1 Jun 2012 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | E210-163B | 99699 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZN |
Netherlands
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| APNP | Duty Type | CONTINUOUS |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.421 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APCN | Coil Quantity | 1 |
| ADZC | Environmental Protection | HERMETIC |
| CBBL | Features Provided | POLARIZED |
| AXHR | Mounting Facility Type And Quantity | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| CQYJ | Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
| ABTD | Mounting Slot Width | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CRNG | Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 110.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 200.0 AC AND 28.0 DC |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| ABKW | Overall Height | 1.010 INCHES MAXIMUM |
| ABHP | Overall Length | 1.718 INCHES MAXIMUM |
| ABMK | Overall Width | 0.515 INCHES MAXIMUM |
| APNA | Winding Dc Resistance Rating | 5.0 KILOHMS NOMINAL SINGLE WINDING |
| AKDX | Winding Quantity | 1 |
| TTQY | Terminal Type And Quantity | 2 PIN ENERGIZING ELEMENT |
| TTQY | Terminal Type And Quantity | 6 PIN CONTACTS |