5945-01-078-8540

RELAY,ELECTROMAGNETIC


5945-01-078-8540 (5945010788540, 010788540)
Part Number (1 listing): E410-182B
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 20 Jun 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-078-8540 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
E410-182B3 - Design Control Reference2 - Production ItemDRI RELAYS INC.  99699    CAGE 99699  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-078-8540 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945010788540A0330032512X1ANG20 Jun 1979
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

010788540

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-078-8540

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

20 Jun 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-078-8540 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZN011 Apr 1991
ZU011 Apr 1991
ZB011 Dec 2006
ZH011 Sep 2009
VD011 Jun 2012
ZX011 Aug 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-078-8540 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
432ETXDE410-182B  99699   CAGE/99699
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-01-078-8540 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597020 Jun 1979
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Jun 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-078-8540 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZN
Code Definitions

ZN

Originating Activity Code (ORIG_ACTY_CD_4210)


Netherlands

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-078-8540 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
APNQArc Quenching MethodAIR
ADTVCase MaterialMETAL
CSQJCenter To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCNCoil Quantity1
ADZCEnvironmental ProtectionHERMETIC
CBBLFeatures ProvidedPOLARIZED
AFJNFragility FactorMODERATELY RUGGED
AJSSFrequency In Hertz60.0 NOMINAL
CBMECubic Measure2.060 CUBIC INCHES
CQYJMounting Facility PatternTRIANGLE SINGLE MOUNTING FACILITY
AXHRMounting Facility Type And Quantity3 SLOTTED HOLE SINGLE MOUNTING FACILITY
ABTDMounting Slot Width0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
CTDLMain Contact Load Current Rating At Maximum Rated Voltage2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD
CTDLMain Contact Load Current Rating At Maximum Rated Voltage4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD
CWABMain Contact Maximum Voltage Rating In Volts115.0 AC AND 28.0 DC
PRMTPrecious MaterialGOLD
PMLCPrecious Material And LocationTERMINAL SURFACES GOLD
AKSLPurpose For Which DesignedGENERAL
ABKWOverall Height1.280 INCHES MAXIMUM
ABHPOverall Length1.718 INCHES MAXIMUM
ABMKOverall Width0.515 INCHES MAXIMUM
CRXHTime Delay0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity14 PIN ALL FUNCTIONS


Back to Top
Back to Top