5945-01-106-9022

RELAY,ELECTROMAGNETIC


5945-01-106-9022 (5945011069022, 011069022)
Part Numbers (2 listings): 7012NKL | 2412NKL |
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 28 Jan 1981

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-106-9022 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7012NKL3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS/AGASTAT RELAYS  89020    CAGE 89020  
2412NKL3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS/AGASTAT RELAYS  89020    CAGE 89020  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-106-9022 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945011069022A0330032512X1ANS28 Jan 1981
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

011069022

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-106-9022

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

28 Jan 1981

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-106-9022 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
B4811H1 Feb 2004
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-106-9022 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325482412NKL  89020   CAGE/89020
325487012NKL  89020   CAGE/89020
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-01-106-9022 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX023 Apr 1982
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

23 Apr 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-106-9022 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
48
Code Definitions

48

Originating Activity Code (ORIG_ACTY_CD_4210)


Federal Aviation Administration, Oklahoma City, OK 73125

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5945-01-106-9022 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
GEG69GU1EA0
Code Definitions

G69

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Department of Transportation, Federal Aviation Administration, ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082, Oklahoma City, OK 73125-0082

G

Acquisition Advice Code (AAC_2507)


GENERAL SERVICES ADMINISTRATION (GSA)/CIVIL AGENCY INTEGRATED MATERIEL MANAGED, STOCKED AND ISSUED Identifies GSA/Civil Agency-managed items available from GSA/Civil Agency supply distribution facilities. Requisitions and fund citations will be submitted in accordance with GSA/Civil Agency/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

GE

Service / Agency Code (MOE_CD_2833)


Federal Aviation Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-106-9022 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
APNQArc Quenching MethodAIR
CWGMAuxiliary Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD
CSQCAuxiliary Contact Maximum Voltage Rating In Volts480.0 AC
ADTVCase MaterialPLASTIC
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.750 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.500 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.880 INCHES NOMINAL FIRST MOUNTING FACILITY
APCNCoil Quantity1
AFRGContact MaterialSILVER
CWJBEnergizing Element Power Rating8.0 WATTS
ADZCEnvironmental ProtectionDUSTPROOF
AFJNFragility FactorMODERATELY RUGGED
CBMECubic Measure62.565 CUBIC INCHES
CQYJMounting Facility PatternRECTANGULAR FIRST MOUNTING FACILITY
CQYJMounting Facility PatternRECTANGULAR SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity4 THREADED HOLE SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity6 UNTHREADED HOLE FIRST MOUNTING FACILITY
CQJXNominal Thread Size0.164 INCHES SECOND MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSKPNonpile-Up Auxiliary Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts240.0 AC AND 30.0 DC
PMLCPrecious Material And LocationC0NTACTS SILVER
PRMTPrecious MaterialSILVER
AKSLPurpose For Which DesignedGENERAL
ABKWOverall Height6.230 INCHES MAXIMUM
ABHPOverall Length3.250 INCHES NOMINAL
ABMKOverall Width3.090 INCHES MAXIMUM
CRXHTime Delay1.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 300.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
AEBVUnthreaded Mounting Hole Diameter0.199 INCHES NOMINAL FIRST MOUNTING FACILITY
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity11 SCREW ALL FUNCTIONS
AAJDThread Class2B SECOND MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND SECOND MOUNTING FACILITY
THSDThread Series DesignatorUNC SECOND MOUNTING FACILITY
CMLPThread Quantity Per Inch32 SECOND MOUNTING FACILITY


Back to Top
Back to Top